期刊文献+

声辐射力脉冲成像技术在评估颈部血管斑块中的应用价值 被引量:13

Application Value of Acoustic Radiation Force Impulse Imaging in the Evaluation of Cervical Vessel Plaque
下载PDF
导出
摘要 目的探讨声辐射力脉冲(ARFI)成像技术在评估颈部血管斑块中的临床价值。方法分别对108例缺血性脑卒中患者(观察组)和97例非心脑血管病人(对照组)进行超声检查,并利用ARFI技术测量斑块的剪切波速度。比较观察组与对照组的斑块发生率、构成、稳定性以及剪切波速度均值。结果观察组的斑块发生率明显大于对照组,差异有统计学意义(P<0.05);观察组与对照组的剪切波速度均值无统计学差异(P>0.05);观察组与对照组斑块构成无统计学差异(P>0.05);观察组不稳定斑块所占比例较对照组高。结论 AFRI技术对检测颈部血管斑块具有重要的临床意义,值得推广。 Objective To explore the application value of acoustic radiation force impulse (ARFI) imaging in the evaluation of cervical vessel plaque.Methods 108 patients with ischemic stroke as observation group and 97 patients without ischemic stroke as control group were all examined by ultrasound and their shear wave velocity (SWV) were measured by ARFI imaging technology. The occurrence rate, composition, stability of plaques as well as the average SWV of the two groups were compared.Results Between the two groups, the occurrence rate of plaque in observation group was significantly higher (P〈0.05); there was no signiifcant difference in the average SWV (P〉0.05); the composition of plaque was significantly different (P〉0.05) and the proportion of unstable plaques in observation group was higher.Conclusion ARFI imaging which can play an important role in evaluating cervical vessel plaque is worthy to be widely applied.
出处 《中国医疗设备》 2014年第11期160-162,173,共4页 China Medical Devices
关键词 声辐射力脉冲成像技术 颈动脉粥样斑块 剪切波速度 缺血性脑卒中 acoustic radiation force impulse imaging carotid atheromatous plaque shear wave velocity ischemic stroke
  • 相关文献

参考文献8

二级参考文献175

  • 1郑冬杏,洪贵英,黄春燕,苏海丹.脑-心综合征患者心电图异常因素分析及护理[J].现代护理,2005,11(13):1025-1026. 被引量:3
  • 2袁桂莉,王义成.颈动脉超声在动脉粥样硬化性疾病检测中的应用[J].中华老年心脑血管病杂志,2005,7(5):349-350. 被引量:35
  • 3罗建文,邵金华,白净,崔立刚,王金锐.瞬时弹性成像用于肝纤维化的无创评价[J].中华肝脏病杂志,2006,14(5):395-397. 被引量:48
  • 4沈镭,陆伦根.瞬时弹性测定在肝纤维化非创伤性诊断中的应用[J].中华消化杂志,2006,26(11):788-790. 被引量:10
  • 5Wang CZ,Guo JY,Zheng YP,et al.Muscle elasticity measurement using ultrasound at isometric step contraction,Aug, 2010[C].6th World Congress of Biomechanics(WCB),Singapore: 2010.
  • 6Wang CZ.Development of a vibro-ultrasound method for muscle stiffness measurement in vivo[D].Hong Kong:Hong Kong Polytechnic University,2010.
  • 7Wang CZ,Zheng YP.Development of a vibro-ultrasound method for skeleton muscle stiffness assessment under high intensity step isometric contraction levels[C].10th International Tissue Elasticity Conference,USA:Arlington,Texas,2011.
  • 8Sandrin L,Tanter M,Catheline S,et al.Shear modulus imaging with 2-D transient elastography[J].IEEE Trans Ultrason Ferroelectr Freq Control,2002,49(4):426-435.
  • 9Sandrin L,Fourquet B,Hasquenoph JM,et al.Transient elastography:a new noninvasive method for assessment of hepatic fibrosis[J].Ultrasound Med Biol,2003,29(12):1705-1713.
  • 10Castera L,Vergniol J,Foucher J,et al.Prospective comparison of transient elastography,fibrotest, APRI,and liver biopsy for the assessment of fibrosis in chronic hepatitis C [J].Gastroenterology, 2005,128(2):343-350.

共引文献92

同被引文献133

引证文献13