摘要
将液相色谱仪检定规程JJG 705–2014与JJG 705–2002在检定方法、检定条件、技术指标三个方面进行对比并说明更改的缘由,对新规程进行详细解读,重点介绍新规程变化内容,最后介绍增加蒸发光散射检测器的缘由及指标。新规程使检定方法更合理,提高了检定效率,满足了市场发展的需要。
It was compared from three aspects of verification method, condition, technical indexes about the difference between JJG 705-2014 and JJG 705-2002, and the reason of changes was given. It had a detailed interpretation of the new regulation and focuse on the changes of the content. At the end it explained the reason of adding a new detector of Evaporative Light Scattering Detector and introduced the indexes of ELSD. The method of the new verification regulation was more responsible, and it improved the verification efficiency and met the needs of the development of the market.
出处
《化学分析计量》
CAS
2014年第6期88-90,共3页
Chemical Analysis And Meterage
基金
国家重大科学仪器设备开发专项(2013YQ51039104)
关键词
液相色谱仪
检定规程
指标
检测器
liquid chromatographs
verification regulation
index
detector