用三维空间标记法测量口腔印模材料的体积变化率 被引量:4

Evaluation of time-dependent dimensional stability of 4 impression materials with labeling by space-measurement
下载PDF
导出
摘要 目的:使用三维标记法测定4种常用印模材体积变化率.方法:每种印模材在金属母模上制取3份试件后使用形状轮廓扫描仪扫描及建模,通过专用软件在试件模型上划出标记空间,并测量不同存放时间标记空间内体积,计算试件的体积变化率.结果:CAVEX藻酸盐在15、180 min时体积变化率分别为1.432%、8.343%;Zhermark藻酸盐在15、180 min时体积变化率分别为1.772%、7.580%;Express XT Penta H硅橡胶在1、36 h体积变化率分别为0.047%、0.364%;Impregum Penta聚醚橡胶在1、36 h体积变化率分别为0.012%、0.336%.2种藻酸盐体积变化率间无统计学差异(P>0.05),2种人工合成橡胶体积变化率间的差值无统计学意义(P>0.05),藻酸盐与人工合成橡胶体积变化率间差值具有统计学意义(P<0.01).结论:藻酸盐类印模材体积变化率大于人工合成橡胶类印模材;三维空间标记法适用于印模试件形变的直接测量. Aim:To investigate the dimensional changes of 4 impression materials.Methods:An alu-minum alloy model and a custom tray were fabricated.Impression samples with 4 impression materials (including 2 alginate materials and 2 elastomers)were made from a reference model.All samples were scanned and evaluated for volumetric changes by using a 3D microscope measurement with space labe-ling.Results:The volumetric change rate of CAVEX alginate samples was 1.432% in 15mins,and was 8.343% in 180 mins;while the volumetric change rate of Zhermark alginate samples was 1.772% in 15mins,and was 7.580% in 180mins;however,the volumetric change rate of ExpressXT Penta H sili-cone samples was 0.047% in 1hour,and was 0.364% in 36 hours;while that of Impregum Penta poly-ether samples was 0.012% in 1hour,and was 0.336% in 36 hours.There was no statistical difference (P >0.05)in volumetric change rates between CAVEX and Zhermark alginate samples,and also no sta-tistical difference(P >0.05)in volumetric change rates between ExpressXT Penta H silicone and Imp-regum Penta polyether samples either.Statistical differences of volumetric change rates were found be-tween alginate materials and elastomers.Conclusion:Dimensional stability of elastomeric materials was better than that of alginate materials.The space-labeling method is a feasible and direct measurement for dimensional staability of impression materials.
出处 《暨南大学学报(自然科学与医学版)》 CAS CSCD 北大核心 2014年第6期538-542,共5页 Journal of Jinan University(Natural Science & Medicine Edition)
基金 广东省自然科学基金项目(31912)
关键词 空间标记法 体积变化率 直接测量 印模形变 三维测量 space-labeling volumetric change rates direct measurement impression deformation three-dimensional measurement
  • 相关文献

参考文献12

  • 1何浩,林映荷.口腔印模精确性的影响因素[J].广东牙病防治,2008,16(9):428-430. 被引量:6
  • 2YY0493-2004,牙科学弹性体印模材料[S].2004:3.
  • 3顾斌,马轩祥,刘杰.超硬石膏材料水粉比对模型精度和表面硬度的影响[J].口腔颌面修复学杂志,2005,6(4):290-292. 被引量:10
  • 4YY1027-2001,齿科藻酸盐印模材料[S].2001:2.
  • 5LEVARTOVSKYS,ZALISM,PILOR,etal.Theeffectofone-stepvs.two-stepimpressiontechniquesonlong-termaccuracyanddimensionalstabilitywhenthefinishlineiswithinthegingivalsulculararea[J].JProsth-odont,2014,23(2):124-133.
  • 6PUJARIML,GARGP,PRITHVIRAJDR.Evaluationofaccuracyofcastsofmultipleinternalconnectionim-plantprosthesisobtainedfromdifferentimpressionmateri-alsandtechniques:invitrostudy[J].JOralImplantol,2014,doi:10.1563/AAID-JOI-D-10-00207.
  • 7宫耀,李烨侃,陈洁,魏斌,沈刚.正圆形圆洞标记法测量口腔不规则藻酸盐印模形变的实验研究[J].上海交通大学学报(医学版),2012,32(6):775-778. 被引量:5
  • 8SHAH S,SUNDARAM G,BARTLETTD,etal.Theuseofa3Dlaserscannerusingsuperimpositionalsoftwaretoassesstheaccuracyofimpressiontechniques[J].JDent,2004,32(8):653-658.
  • 9TODDJA,OESTERLELJ,NEWMANSM,etal.Di-mensionalchangesofextended-pouralginateimpressionmaterials[J].Am JOrthodDentofacialOrthop,2013,143(4Suppl):S55-S63.
  • 10VITTIRP,DASILVAMA,CONSANIRL,etal.Di-mensionalaccuracyofstonecastsmadefrom silicone-basedimpressionmaterialsandthreeimpressiontech-niques[J].BrazDentJ,2013,24(5):498-502.

二级参考文献52

  • 1夏勇,黄翠.3种印模材料制取活动义齿模型的三维精度比较[J].口腔医学研究,2004,20(5):514-516. 被引量:4
  • 2刘奕,陈吉华,王迎捷,赵三军,熊宇.添加抗菌剂藻酸盐印模材料复制精度的研究[J].临床口腔医学杂志,2006,22(6):360-362. 被引量:8
  • 3李金华,王雪,刘虹.加强Ⅳ型石膏弯曲强度的实验研究[J].口腔材料器械杂志,2007,16(1):31-33. 被引量:2
  • 4Federick DR, Caputo A. Comparing the accuracy removable hydrocolloid and elastomaric impression materials[J ]. J Am Dent Assoc, 1997, 128(2): 183-8.
  • 5Glen P, McGivney AB, David B. McCracken's removable partial prosthodontics [M ]. 10th ed. St Louis: Mosby Publishing Co. Inc, 2000: 221.
  • 6Hassan AK. Dimensional accuracy of 3 silicone dental impression materials [ J -. East Mediterr Health J, 2006, 12(5): 632-6.
  • 7Hiraguchi H, Nakagawa H, Wakashima M, et al. Effect of storage period of alginate impressions following spray with disinfectant solutions on the dimensional accuracy and deformation of stone models[J ]. Dent Mater J, 2005, 24(1): 36-42.
  • 8Shah S, Sundaram G, Bartlett D, et al. The use ofa 3D laser scanner using superimpositional software to assess the accuracy of impression techniques[ J ]. J Dent; 2004, 32(8): 653-8.
  • 9Eriksson A, Ockert-Eriksson G, Lockowandt P. Accuracy of irreversible hydrocolloids for fixed prosthodontics [J]. Eur J Oral Sci, 1998, 106(2Pt1): 651-60.
  • 10Brosky ME, Major R J, DeLong R, et al. Evaluation of dental arch reproduction using 3D optical digitization [J ]. J Prosthet Dent, 2003, 90(5): 434-9.

共引文献27

同被引文献24

引证文献4

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部