期刊文献+

计算机辅助设计个体化经皮空心螺钉内固定治疗腕舟骨骨折的应用 被引量:7

Application of individualization percutaneous cannulated screws fixation with the help of computer-assisted design in carpal scaphoid fracture
下载PDF
导出
摘要 目的利用Mimics软件设计一种腕舟骨骨折个体化掌侧经皮空心螺钉置钉技术。方法将24例成人腕舟骨骨折腕关节CT扫描数据导入Mimics软件,在Mimics软件中进行腕关节三维重建,模拟舟骨手术,制定舟骨个体化置钉参数并模拟置钉,据此参数在腕舟骨上经皮置钉。术后行腕关节CT扫描,验证置钉准确性。结果 Mimics重建图像和CT扫描的腕舟骨参数差异无统计学意义,能准确反映舟骨三维立体结构。用该方法对24例成人腕舟骨骨折行经皮空心螺钉固定,术后CT显示螺钉位置良好,随访腕关节功能良好。结论用Mimics软件对腕关节进行三维重建,模拟手术,测量、制订详细合理的个体化置钉参数,可优化手术方案与方式,减少并发症,降低手术风险,提高临床治疗效果。 Objective To provide a individualization volar percutaneous cannulated screws fixation with the help of Mimics-assisted design in carpal scaphoid fracture surgery. Methods Three-dimensional reconstruction of 24 CT scanned adult carpal scaphoid fractures were performed by using Mimics software. The operations were analogued in Mimics software and then individual fixation parameters were designed. Based on which percutaneous cannulated screws fixation of carpal scaphoid fracture were performed under Mimics individual fixation parameters. The accuracy of postoperation was assessed by CT scanning. Results There was no statistical difference in parameters of the CT scan and Mimics reconstruction images, which could reflect carpal scaphoid accurate three dimensional structure. Postoperation CT scanning showed that the cannulated screws were fixed successfully in 24 adult carpal scaphoid frac-tures. The function of wrists were well in follow-up. Conclusions Three-dimensional reconstruction of the carpal scaphoid by using mimics software, sham operated,measurement and design individual screw fixation parameters, can optimize operation schedule and method,decrease operation complication and risk, improve treatment effectiveness of clinical.
出处 《临床骨科杂志》 2014年第6期659-663,共5页 Journal of Clinical Orthopaedics
关键词 计算机辅助 个体化 经皮 舟骨骨折 空心螺钉 computer-assisted individualization percutaneous scaphoid fracture cannulated screws
  • 相关文献

参考文献9

  • 1Krimmer Schmitt R, Herbert T, Scaphoid fractures--diagnosis, classification and theraphy [ J ]. Unfallcharurg, 2000, 103 ( 10 ) : 812 -819,.
  • 2Duckworth A D,Jenkins P J, Aitken S A, et al. Scaphoid fracture epidemiology[ J]. J Trauma Acute Care Surg,2012, 72(2) :41 - 45.
  • 3Bethel J. Seaphoid fracture : diagnosis and management [ J ]. Emerg Nurse,2009,17 (4) :24 - 29.
  • 4Dias J J, Dhukaram V, Abhinav A, et al. Clinical and radiological outcome of cast immobilisation versus surgical treatment of acute scaphoid fractures at a mean fallow-up of 93 months [ J ]. J Bone Joint Surg Br,2008,90(7) :899 -905.
  • 5McQueen M M, Gelbke M K, Wakefield A, et al. Percutaneous screw fixation versus conservative treatment for fractures of the waist of the scaphoid:a prospective randomised study[J]. J Bone Joint Surg Br,2008,90( 1 ) :66 -71.
  • 6洪海森,郭林新,洪加源.经皮Herbert螺钉治疗腕舟骨骨折[J].临床骨科杂志,2011,14(6):676-677. 被引量:8
  • 7Modi C S, Nancoo T, Powers D, et al. Operative versus nonoperative treament of acute undisplacement and minimally displaced scaph- oid waist fractures :A systematic review[ J]. Injury ,2009,40( 3 ) : 268 - 273.
  • 8王军强,孙磊,王满宜.计算机辅助骨科手术的应用和进展[J].中华创伤骨科杂志,2004,6(1):110-114. 被引量:38
  • 9洪加源,林达生,练克俭,丁真奇,翟文亮.两种内固定方式治疗腕舟骨骨折的临床疗效对比[J].临床骨科杂志,2013,16(3):287-289. 被引量:17

二级参考文献14

  • 1洪海森,郭林新,洪加源.经皮Herbert螺钉治疗腕舟骨骨折[J].临床骨科杂志,2011,14(6):676-677. 被引量:8
  • 2Cooney W P, Linscheid R L, Dobyns J H, et al. Scaphoid nonun- ion: role of anterior interpositional bone grafts [ J ] J Hand Surg (Am), 1988,13(5) :635 -650.
  • 3Bhandari M, Hanson B P, Acute nondisplaced fractures of the scaphoid [ J ]. J Orthop Trauma, 2004, 18 (4) :253 - 255.
  • 4Cooney W P 3rd. Scaphoid fractures: current treatments and tech- niques[ J ]. fnstr Course Leer, 2003,52 : 197 - 208.
  • 5Arora R, Gschwentner M, Krappinger D, et al. Fixation of non- displaced scaphoid fractures : making treatment cost effective : Pro- spective controlled trial [ J ]. Arch Orthop Trauma Surg, 2007, 127(1) : 39 -46.
  • 6Retting A C. Management of acute scaphoid fractures[ J]. Hand Clin, 2000, 16(3) : 381 -395.
  • 7Gabler C, Kukla C, Breitenseher M J, et al. Diagnosis of occult scaphoid fractures and other wrist injuries: are repeated clinical examinations and plain radiographs still state of the art? [ J]. Lan- genbecks Arch Sm'g, 2001, 386(2) : 150 -154.
  • 8Chatuparisute P, Kunatippapong N. Geometry of carpal scaphoid in Thais: anatomical study [ J ]:l Med Assoc Thai, 2003, 86 (5) : 457 -461.
  • 9Jeon I H, Oh G W, Park B C, et al. Minimal invasive percutane- ous Herbert screw fixation in acute unstable scaphoid fracture[ J]. J Hand Surg(Am), 2003, 8(2) : 213 -218.
  • 10Christodoulou L S, Kitsis C K, Chanberlain S T. Internal fixation of scaphoid non-union: a comparative study of three methods[ J]. Injury, 2001,32(8) :625 -630.

共引文献59

同被引文献58

引证文献7

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部