期刊文献+

基于互相关算法的飞机导线故障诊断与定位系统设计 被引量:11

Design of Fault Diagnosis and Localization System of Aircraft Wire Based on Cross-correlation Algorithm
下载PDF
导出
摘要 以飞机导线短路故障和断路故障为研究对象,目的在于寻求一种测试方法能够提高应用时域反射测量原理进行故障诊断与定位的精度;按照实际机场工程应用背景,设计了以便携式工控机为控制核心、以LabVIEW为驱动软件的飞机导线故障诊断与定位系统;根据信号传播特性,提出了基于互相关算法的故障定位方法,消除了系统误差的影响;计算机仿真和实物测试结果表明该系统具有测试过程方便、准确性高的优点,对提高民航机务维修质量具有促进作用。 In order to improve the accuracy received by the short circuit fault and the open circuit fault diagnosis and localization of the aircraft wire based on the time domain reflection measurement principle,a control method is proposed.According to the engineering application background of the actual airport,the wire fault diagnosis and localization system is designed,of which the industrial control computer is the control core and the LabVIEW is the driver software.By making use of the method of the cross-correlation algorithm,the system error is eliminated.The simulation and the experiment results show that the test process is convenient and accurate,which can improve the repair quality of the Chinese civil aviation.
作者 刘晓琳 袁昆
出处 《计算机测量与控制》 北大核心 2014年第12期3903-3905,共3页 Computer Measurement &Control
基金 国家自然科学基金项目(U1333111)
关键词 飞机导线 故障诊断与定位 互相关算法 aircraft wire fault diagnosis and localization cross-correlation algorithm
  • 相关文献

参考文献6

  • 1高振清,乔陆.基于光谱触发的电气线路放电故障检测[J].计算机测量与控制,2013,21(9):2369-2371. 被引量:2
  • 2Nve X,Zan M,Yi T.Selection of Wiring Environment and Failure Rate Comparison Analysis in Aircraft Wiring Risk Assessment[J] .Procedia Engineering,2011,14:428-432.
  • 3Bouchekara H,Smail M K,Dahman G.Diagnosis of multi-fault wiring network using time-domain reflectometry and electromagnetism-like Mechanism[J] .Electromagnetics,2013,33 (2):131-143.
  • 4Zhang X L,Zhang M M,Liu D M.Reconstruction of Faulty Cable Network Using Time-domain Reflectometry[J] .Progress in Electromagnetics Research,2013,136:457-478.
  • 5张俊民,魏娟,谢华博,曹大树,姚红宇.基于时域反射法的航空导线绝缘故障检测与分析[J].航空学报,2009,30(4):706-712. 被引量:20
  • 6Parkey C,Hughes C,Locken N.Analyzing Artifacts in the Time Domain Waveform to Locate Wire Faults[J] .IEEE Instrumentation and Measurement Magazine,2012,15 (4):16-21.

二级参考文献15

  • 1吴伟,郭勇,程俊东.基于PXI总线技术的飞机电气综合测试系统[J].计算机测量与控制,2004,12(9):804-806. 被引量:18
  • 2陈涛,何为,刘晓明,熊东.高压输电线路紫外在线检测系统[J].电力系统自动化,2005,29(7):88-92. 被引量:52
  • 3梁志刚,陈云敏,陈仁朋,陈赟.同轴电缆电磁波反射技术监测滑坡研究[J].岩土工程学报,2005,27(4):453-458. 被引量:19
  • 4Furse C, Haupt R. Down to the wire[J]. IEEE Spectrum, 2001, 38(2):34- 39.
  • 5Dowding C H, Dussud M L, Kane W F, et al. Monitoring deformation in rock and soil with TDR sensor cables[J]. Geotechnical News, 2003, 21(2):51-59.
  • 6Dussud M L. TDR monitoring of soil deformation: case histories and field techniques [D]. Evanston, Illinois: Northwestern University, 2002.
  • 7Griffiths L A, Parakh R, Cynthia Furse, et al. The in visible fray: a critical analysis of the use of reflectometry for fray location[J]. IEEE Sensors Journal, 2006, 6(3): 697- 706.
  • 8Chung Y C, Furse C, Pruitt J, et al. Application of phase detection frequency domain reflectometry for locating faults in an F- 18 flight control harness[J]. IEEE Transactions on Electromagnetic Compatibility, 2005,47(2) :327- 333.
  • 9邱关源.电路[M].4版.北京:高等教育出版社,2001:426-460.
  • 10国防科学技术工业委员会.GJB773.1-19航空用氟碳树脂绝缘电线电缆[S].北京:国防科工委军标出版发行部,1994.