摘要
采用"曝气生物滤池-超滤-反渗透"工艺处理由污水处理厂排水、滤池反洗水、清净下水以及厂区生活污水混合而成的废水,工程运行结果表明,COD,BOD,氨氮、浊度、电导率的去除率分别为68.06%,77.93%,72.73%,97.37%,99.17%,出水p H为7.2,本系统出水水质满足循环水补水水质要求。
The BAF(biological aerobic filter)-UF(ultra filtration)-RO(reverse osmosis)process is adopted to treat the wastewater, which is consisted of the drain of wastewater treatment plant, the back washing water, the clear drain and plant area sewage. The result shows the removal rate of COD, BOD, NH4+ -N, turbidity and conductivity reaches 68. 06%, 77. 93%, 72. 73%, 97. 37% and 99. 17% respectively and pH is 7. 2. The output water meets the criteria specified of industrial cir-culating cooling water.
出处
《工业安全与环保》
北大核心
2014年第12期12-14,共3页
Industrial Safety and Environmental Protection
基金
"水体污染控制与治理"国家科技重大专项(2008ZX07208-002
2012ZX07208-005
2012ZX07212-001)
辽宁省科学技术计划项目任务(2011229001
2013003008)
关键词
曝气生物滤池
超滤
反渗透
乙烯厂污水
循环回用
biological aerobic filter
ultra filtration
reverse osmosis
ethylene wastewater
recycling and reuse