摘要
介绍某超临界600MW汽轮机监视段压力异常升高限制出力的分析和处理情况,总结了利用弗留格尔公式定量分析和诊断监视段压力升高的一般方法。揭缸检查结果验证了分析结论,经检修后汽轮机出力恢复正常。
Introduce one 600MW supercritical steam turbine Monitored section Pressure Abnormal Riseing and output limits analysis and treatment, Summarizes the general method of analysis and diagnosis monitoring section pressure riseng basis on Friuli Greig formula. The inspection results when thecylinder is opened verify the analysis conclusion,After repair the turbine output return to normal.
出处
《河南电力》
2014年第4期42-44,61,共4页
Henan Electric Power
关键词
超临界
汽轮机
监视段压力
结垢
supercritical
steam turbine
monitoring section Pressure
fouling