摘要
对中国石油辽河石化公司0.6 Mt/a连续重整装置催化剂再生单元注氯系统出现的异常情况:再生注氯泵入口杂质聚集、再生注氯泵安全阀内漏、再生注氯泵入口管线冬季冻凝所引起的再生注氯异常情况进行分析并得出相应的结论及应对措施及建议。
The abnormal conditions of chlorine injection system in catalyst regeneration unit of 0.6Mt/a continuous reforming plant in PetroChina Liaohe petrochemical company were analyzed, such as impurities aggregation at regenerative chloride injection pump inlet, inner leakage of safety valve of regenerative chloride injection pump, winter congealing of regenerative chloride injection pump inlet and so on; countermeasures and suggestions were nronosed.
出处
《辽宁化工》
CAS
2014年第12期1576-1578,共3页
Liaoning Chemical Industry
关键词
连续重整
再生注氯
异常分析
措施及建议
continuous reforming unit
chlorine injection system
problems
solutions