期刊文献+

Reception pattern influence on magnetoacoustic tomography with magnetic induction 被引量:4

Reception pattern influence on magnetoacoustic tomography with magnetic induction
原文传递
导出
摘要 Based on the acoustic radiation theory of a dipole source,the influence of the transducer reception pattern is studied for magnetoacoustic tomography with magnetic induction(MAT-MI).Numerical studies are conducted to simulate acoustic pressures,waveforms,and reconstructed images with unidirectional,omnidirectional,and strong directional transducers.With the analyses of equivalent and projection sources,the influences of the model dimension and the layer effect are qualitatively analyzed to evaluate the performance of MAT-MI.Three-dimensional simulation studies show that the strong directional transducer with a large radius can reduce the influences of equivalent sources,projection sources,and the layer effect effectively,resulting in enhanced pressure and improved image contrast,which is beneficial for boundary pressure extraction in conductivity reconstruction.The reconstructed conductivity contrast images present the conductivity boundaries as stripes with different contrasts and polarities,representing the values and directions of the conductivity changes of the scanned layer.The favorable results provide solid evidence for transducer selection and suggest potential practical applications of MAT-MI in biomedical imaging. Based on the acoustic radiation theory of a dipole source, the influence of the transducer reception pattern is studied for magnetoacoustic tomography with magnetic induction(MAT-MI). Numerical studies are conducted to simulate acoustic pressures, waveforms, and reconstructed images with unidirectional, omnidirectional, and strong directional transducers.With the analyses of equivalent and projection sources, the influences of the model dimension and the layer effect are qualitatively analyzed to evaluate the performance of MAT-MI. Three-dimensional simulation studies show that the strong directional transducer with a large radius can reduce the influences of equivalent sources, projection sources, and the layer effect effectively, resulting in enhanced pressure and improved image contrast, which is beneficial for boundary pressure extraction in conductivity reconstruction. The reconstructed conductivity contrast images present the conductivity boundaries as stripes with different contrasts and polarities, representing the values and directions of the conductivity changes of the scanned layer. The favorable results provide solid evidence for transducer selection and suggest potential practical applications of MAT-MI in biomedical imaging.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第1期329-337,共9页 中国物理B(英文版)
基金 Project supported by the National Basic Research Program of China(Grant No.2011CB707900) the National Natural Science Foundation of China(Grant Nos 11274176 and 11474166) the Priority Academic Program Development of Jiangsu Higher Education Institutions,China
关键词 接收模式 断层摄影 磁感应 重建图像 生物医学成像 三维模拟 换能器 辐射理论 magnetoacoustic tomography with magnetic induction(MAT-MI) reception pattern projection source and equivalent source layer effects
  • 相关文献

参考文献24

  • 1Xu Y and He B 2005 Phys. Med. Biol. 50 5175.
  • 2Li X, Xu Y and He B 2007 IEEE Trans. Biomed. Eng. 54 323.
  • 3Hu G, Li X and He B 2010 Appl. Phys. Lett. 97 103705.
  • 4Hu G and He B 2011 PLoS ONE 6 e23421.
  • 5Xia R M, Li X and He B 2007 Appl. Phys. Lett. 91 83903.
  • 6Hu G and He B 2012 Appl. Phys. Lett. 100 013704.
  • 7Mariappan L and He B 2013 IEEE Trans. Med. Imag. 32 619.
  • 8Li X, Hu S, Li L and Zhu S 2013 Comput. Math. Methods Med. 2013 161357.
  • 9Mariappan L, Hu G and He B 2014 Med. Phys. 41 022902.
  • 10Ma Q Y and He B 2007 Phys. Med. Biol. 52 5085.

同被引文献23