摘要
目的:探讨一种更为简便、快速的测定苯酚滴耳液中苯酚含量的方法。方法:苯酚与4-氨基安替比林在铁氰化钾的作用下,溶液显橙红色,在520 nm处呈最大吸收,可直接用分光光度法测定苯酚的含量。结果:在520 nm测定波长下,苯酚浓度在1.0、1.5、2.0、2.5、3.0、3.5、4.0和4.5μg/m L范围内呈良好的线性关系。回归方程:Y=0.1408X-4.4762×10-3(r=0.999 9,n=3),测定方法的平均回收率为99.72%,平均日内差和日间差RSD分别为0.44%和0.63%;3批样品的含量较为均匀,平均含量为0.196 g/m L,平均RSD为0.63%。结论:该方法较为简便,灵敏,结果准确可靠。
Objective: To develop a simple, effective method for content determination of phenol in phenol ear drops. Methods: Under the effect of potassium ferricyanide, the solution containing phenol and 4-aminoantipyrene showed orange red and the maximum absorption wavelength was 520 nm. The contents was directly determined by spectrophotometric method. Results: With the maximum absorption wavelength being 520 nm, the linear range of phenol was 1.0-4.5 μg/mL (r=0.999 9, n=3), and the regression equation was Y=0.1408X- 4.4762×10^-3. The average recovery rate was 99.72%, and RSD of intra-day and inter-day precision were 0.44% and 0.63%, respectively. No significant difference was found in the contents of the samples determined by established method, with the average content being 0.196 g/mL and RSD 0.63%. Conclusion:The established method is simple, efficient and accurate.