期刊文献+

心率变异率预测高血压患者椎管内麻醉低血压发生的准确性 被引量:4

The Accuracy of Heart Rate Variability as A Predictor of Hypotension after Spina Anesthesia in Hypertensive Patients
下载PDF
导出
摘要 目的:高血压患者行椎管内麻醉后出现低血压是常见的现象,本研究探讨高血压患者行椎管内麻醉后心率变异率是否能够预测低血压的发生。方法:41例高血压患者行椎管内麻醉纳入研究,记录心脏变异率的五个时间点,输入液体前,输入液体后5、15、30 min。液体负荷5 m L/kg乳酸钠林格氏液,基线的变异率,椎管内麻醉后低血压与最高血压的比值,通过计算曲线下面积获得。结果:LF/HF椎管内麻醉后心率无明显差异,LF/HF预测中等低血压的曲线下面积为0.685(P=0.074),严重低血压为0.579(P=0.560)。结论:心率变异率不是椎管内麻醉交感神经阻滞后预测血压变化的可靠指标。 Objective:To evaluate the accuracy of using heart rate variability parameters to predict the occurrence of hypotension.Hypotension is a common phenomenon in hypertensive patients with spinal anesthesia.Method:41 patients undergoing spinal anesthesia were included, heart rate variability was recorded at five different time points such as before fluid loading, after fluid loading as well as 5,15 and 30 min after spinal anesthesia.Fluid loading was performed using 5 m L/kg of a crystalloid solution.Baseline multation power and low to high frequency ratio(LF/HF) in predicting hypotension after spinal anesthesia were analyzed by calculating the area under curves(AUC).Result:LF/HF ratios and total powers did not significantly change after spinal anesthesia.AUCs of LF/HF ratio for predicting moderate hypotension was 0.685(P=0.074), severe hypotension was 0.579(P=0.560).Conclusion:Heart rate variability is not a reliable predictor of hypotension after spinal block in hypertensive patients.
作者 杨春艳
出处 《中国医学创新》 CAS 2015年第4期123-125,共3页 Medical Innovation of China
关键词 高血压 椎管内麻醉 低血压 Hypertension Spinal anesthesia Hypotension
  • 相关文献

参考文献13

  • 1Brown A G,Visram A R,Jones R D,et al.Preoperative and postoperative oxygen saturation in the elderly following spinal or general anaesthesia-an audit of current practice[J].Anaesth Intensive Care,1994,22(2):150-154.
  • 2Carpenter R L,Caplan R A,Brown D L,et al.Incidence and risk factors for side effects of spinal anesthesia[J].Anesthesiology,1992,76(6):906-916.
  • 3Hartmann B,Junger A,Klasen J,et al.The incidence and risk factors for hypotension after spinal anesthesia induction:an analysis with automated data collection[J].Anesth Analg,2002,94(6):1521-1529.
  • 4Hanss R,Ohnesorge H,Kaufmann M,et al.Changes in heart rate variability may reflect sympatholysis during spinal anaesthesia[J].Acta Anaesthesiol Scand,2007,51(10):1297-1304.
  • 5Critchley L A.Hypotension,subarachnoid block and the elderly patient[J].Anaesthesia,1996,51(12):1139-1143.
  • 6Mc Crae A F,Wildsmith J A.Prevention and treatment of hypotension during central neural block[J].Br J Anaesth,1993,70(6):672-680.
  • 7Hanss R,Bein B,Francksen H,et al.Heart rate variability-guided prophylactic treatment of severe hypotension after subarachnoid block for elective cesarean delivery[J].Anesthesiology,2006,104(4):635-643.
  • 8Hanss R,Bein B,Ledowski T,et al.Heart rate variability predicts severe hypotension after spinal anesthesia for elective cesarean delivery[J].Anesthesiology,2005,102(6):1086-1093.
  • 9Hanss R,Bein B,Weseloh H,et al.Heart rate variability predicts severe hypotension after spinal anesthesia[J].Anesthesiology,2006,104(3):537-545.
  • 10Hanss R,Renner J,Ilies C,et al.Does heart rate variability predict hypotension and bradycardia after induction of general anaesthesia in high risk cardiovascular patients?[J].Anaesthesia,2008,63(2):129-135.

同被引文献34

引证文献4

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部