期刊文献+

Calibration of grayscale values of cement constituents using industrial X-ray tomography

Calibration of grayscale values of cement constituents using industrial X-ray tomography
原文传递
导出
摘要 X-ray computer tomography(CT)has been intensively applied to the research of cement-based materials,while most of the CT applications are qualitative.To have more quantitative applications,the arbitrary grayscale values and the specially defined CT numbers of the main cement constituents,including the cement clinkers,the hydrated products,and some durability products are calibrated on an industrial CT system in this study.The calibration results can deepen our understandings of the X-ray CT image of the cement-based materials.The universalities of the calibrated results and the calibration procedures are clarified.The potential applications are anticipated,such as segmentation of the individual phases,quantitative durability research,porosity determinations,and quantitative composition characterizations.
出处 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2015年第3期485-492,共8页 中国科学(技术科学英文版)
基金 supported by the Fundamental Research Funds for the Central Universities(Grant No.2242014R30014) State Key Laboratory of High Performance Civil Engineering Materials of China(Grant No.2012CEM008)
关键词 computer tomography CEMENT CALIBRATION 计算机断层扫描 水泥基材料 校准结果 X射线 灰度值 工业用 成分 工业CT系统
  • 相关文献

参考文献2

二级参考文献15

  • 1Papadakis V G, Vayenas C G and Fardis M N. Fundamental Modeling and Experimental Investigation of Concrete Carbonation [J]. ACI Materials Journal, 1991, 88(4): 363-373.
  • 2Papadakis V G, Vayenas C G and Fardis M N. Experimental Investigation and Mathematical Modeling of the Concrete Carbonation Problems [J]. Chemical Engineering Science, 1991, 46(5-6): 1 333- 1 338.
  • 3Rattanasak U, Kendall K. Pore Structure of Cement / Pozzolan Composites by X-Ray Microtomography [J]. Cement and Concrete Research, 2005, 35(4): 637-640.
  • 4Gallucci E, Scrivener K, Groso A, et aL 3D Experimental Investigation of the Microstructure of Cement Pastes Using Synchrotron X-Ray Microtomography (uCT) [J]. Cement and Concrete Research, 2007, 37(3): 360-368.
  • 5Rougelot T, Burlion N, Bernard D, et al. About Microcracking due to Leaching in Cementitious Composites: X-Ray Microtomography Description and Numerical Approach [J]. Cement and Concrete Research, 2010, 40(2): 271-283.
  • 6Landis E N, Nagy E N and Keane D T. Microstructure and Fracture in Three Dimensions [J]. Journal of Engineering Mechanics, 2003, 70(7): 911-925.
  • 7Stock S R, Naik N K and Wilkinson A P. X-Ray Microtomography (Micro CT) of the Progression of Sulfate Attack of Cement Paste [J]. Cement and Concrete Research, 2002, 32( 10): 1673-1675.
  • 8Bentz D P, Mizell S, Satterfield S, et al. The Visible Cement Data Set [J]. Journal of Research of the National Institute of Standards and Technology, 2002, 107(2): 137-148.
  • 9Gommes C J, Bons A J, Blacher S, et al. Practical Methods for Measuring the Tortuosity of Porous Materials from Binary or Gray- Tone Tomographic Reconstructions [J]. AIChE Journal, 2009, 55(8): 2 000-2 012.
  • 10Flannery B P, Deckman H W, Roberge W G, et al. Three-Dimensional X-Ray Microtomography [J]. Science, 1987, 237(4821): 1439-1443.

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部