结合工程实践,对由多栋超高层建筑组成的城市综合体消防给水系统设计进行了探讨,包括室内消防系统分区形式的确定、减压阀的使用、高区消防泵房的设置、消防转输水箱容积确定、消防水泵接合器的设置等内容,对设计中应注意的问题提出了建议,可供设计人员参考。
Combined with the urban complex composed of multiple door fire system partition form, use engineering practice, the design of the fire water supply system for high-rise buildings was discussed, including the determination of in- of pressure reducing valve, setting of fire pump room in high area, determination of fire water transfer tank volume, setting of fire water pump adaptor and so on. The suggestions for the problems that should be paid attention to in the design were offered to provide reference for designers.
出处
《中国给水排水》
CAS
CSCD
北大核心
2015年第6期39-41,共3页
China Water & Wastewater
关键词
多栋超高层建筑
消防给水
消防泵房
multiple high-rise buildings
fire water supply
fire pump room