期刊文献+

多栋超高层建筑消防给水系统设计探讨 被引量:15

Discussion on Design of Fire Water Supply System for Urban Complex Composed of Multiple High-rise Buildings
原文传递
导出
摘要 结合工程实践,对由多栋超高层建筑组成的城市综合体消防给水系统设计进行了探讨,包括室内消防系统分区形式的确定、减压阀的使用、高区消防泵房的设置、消防转输水箱容积确定、消防水泵接合器的设置等内容,对设计中应注意的问题提出了建议,可供设计人员参考。 Combined with the urban complex composed of multiple door fire system partition form, use engineering practice, the design of the fire water supply system for high-rise buildings was discussed, including the determination of in- of pressure reducing valve, setting of fire pump room in high area, determination of fire water transfer tank volume, setting of fire water pump adaptor and so on. The suggestions for the problems that should be paid attention to in the design were offered to provide reference for designers.
出处 《中国给水排水》 CAS CSCD 北大核心 2015年第6期39-41,共3页 China Water & Wastewater
关键词 多栋超高层建筑 消防给水 消防泵房 multiple high-rise buildings fire water supply fire pump room
  • 相关文献

参考文献3

  • 1GB50045--95,高层民用建筑设计防火规范(2005年版)[S].北京:中国计划出版社,2005.
  • 2GB50084-2001,自动喷水灭火系统设计规范(2005年版)[S].北京:中国计划出版社,2005.
  • 3住房和城乡建设部工程质量安全监管司,中国建筑标准设计研究院.全国民用建筑工程设计技术措施:给水排水[M].北京:中国计划出版社,2009.

共引文献13

同被引文献33

引证文献15

二级引证文献38