期刊文献+

不同效应室浓度舒芬太尼复合丙泊酚对Narcotrend的影响 被引量:3

Influence of Different Effect Compartment Concentration of Sufentanil Combined with Propofol on Narcotrend
原文传递
导出
摘要 目的:探讨靶控输注不同效应室浓度的舒芬太尼复合丙泊酚对Narcotrend指数(NI)的影响。方法:选择60例全麻患者,年龄40-60岁,体重指数<30 kg/m2,ASAⅠ-Ⅱ级,随机分为4组(n=15):舒芬太尼效应室靶控浓度0.1 ng/m L(A组)、0.2 ng/m L(B组)、0.3 ng/m L(C组)、0.4 ng/m L(D组);各组舒芬太尼达效应室靶浓度5 min后给予丙泊酚1 mg/kg。记录实验过程中的血压、心率、血氧饱和度及NI。所有患者在实验结束后,均调整至适宜的麻醉深度,给与阿曲库胺,进行气管插管。结果:靶控输注舒芬太尼使各组的NI有不同程度的降低,随着靶控浓度的增加,降低幅度增大;单纯靶控输注舒芬太尼时,其效应室浓度与NI呈负相关,相关系数为-0.456。结论:舒芬太尼能降低NI,舒芬太尼效应室浓度与NI呈负相关。而舒芬太尼效应室浓度0.4 ng/m L复合丙泊酚后,NI反而呈短暂的上升,随后下降的现象。 Objective: To investigate the effects of different effect compartment of sufentanil combined with propofol by target controlled infusion on Narcotrend index. Methods: 60 patients, aged 40.-450, weight index〈30 kg/m2, ASA Ⅰ-Ⅱ undergoing general anes- thesia were randomly divided into 4 groups (n=l 5): sufentanil effect compartment concentration 0.1 ng/mL (group A), 0.2 ng/mL(group B), 0.3 ngmL (group C), and 0.4 ng/mL (group D). The propofol of 1.0 mg/kg was administered after 5 min when the concentration of sufentanil reached the effect compartment concentration. The parameters of BP, FIR, SpO2 and Narcotrend index(NI) were recorded dur- ing proceeding of experiments. After experiments, all of patients were adjusted to appropriate anesthesia depth, then the muscle relaxants were administered and the tracheal intubations were done. Results: The NI decreased in varying degree with target injection of sufentanil, accompanied with the increase of target concentration, the trend of decrease is more obvious. During target-controlled infusion of sufen- tanil as sole, there was a negative correlation between the effect compartment concentration and NI, and the correlation index is -0.456. After 1 min of injecting propofol, the NI of Group D ascended initially, with statistical significance in comparison among groups (P〈0. 05), then the Nil was decreased with the time. Conclusion: Sufentanil can decrease the NI, and the correlation between the effect com- partment concentration and NI is negative, while sufentanil of 0.4 ng/mL effect compartment concentration combined with propofol caused the phenomenon that the NI raised temporarily, whereafter decreased.
出处 《现代生物医学进展》 CAS 2015年第7期1290-1293,共4页 Progress in Modern Biomedicine
基金 黑龙江省科学基金重点项目(ZD201017)
关键词 舒芬太尼 靶控输注 效应室浓度 丙泊酚 Sufentanil Targeted controlled injection Effect compartment concentration Propofol
  • 相关文献

参考文献18

  • 1Kreuer S, Bruhn J, Walter E, et al. Comparative pharmacodynamic modeling useing bispectml and narcotrend-index with and without a pharmacodynamic plateau during sevoflurane anesthesia [J]. Anesth Analg, 2008, 106:1171-1181.
  • 2胡明新,杨军,冯增光,蔡传湘,谭熠,邓宁.阿片类药物对大脑状态指数和丙泊酚的效应室靶浓度的影响[J].临床麻醉学杂志,2009,25(9):782-785. 被引量:8
  • 3Benthuysen JL, Foltz BD, Smith NT, et al. Prebypass hemodynamic stability of sufentanil, fentanyl, and morphine anesthesia during car- diac surgery: a comparison of cardiovascular profiles[J]. J Cardiotho- rae Anesth, 1988,2(6): 749-757.
  • 4刘礼胜,张兴安.舒芬太尼与丙泊酚药动学、药效学相互作用[J].中国新药与临床杂志,2009,28(7):481-485. 被引量:4
  • 5Aime I, Gayat E, Fermanian C, et al. Effect of age on the compara- bility ofbispectral and stste entropy indices during the maintenance of propofol-sufentanil anaerthesia [J]. British Journal of Anaerthesia, 2012, 108(4): 638-643.
  • 6Panousis P, Heller AR, Burghardt M, et al. The effects of electromyo- graphic activity on the accuracy of the Nareotrend monitor compared with the Bispectral Index during combined anaesthesia [J]. Anaesthe- sia, 2007, 62(9): 868-874.
  • 7Bailey PL, Streisand JB, East KA, et al. Differences in magnitude and duration of opiod induced respiratory depression and analgesia with fentanyl and sufentanil[J]. Anesth Analg, 1990, 70(1): 8-15.
  • 8钱晓岚,张卫.不同靶浓度舒芬太尼对丙泊酚静脉麻醉脑电双频指数的影响[J].医学信息(手术学分册),2008,21(11):974-975. 被引量:6
  • 9Sharer S, Varvel JR. Pharmacokinetics, pharmacodynamics, and ratio- nal opioid selection[J]. Anesthesiology, 1991, 74(1): 53-63.
  • 10Ferreira DA, Nunes CS, Antunes LM, et al. The effect of a remifen- tanil bolus on the bispectml index of the EEG (BIS) in anaesthetized patients independently fIom intubation and surgical stimuli [J]. Eur J Anaesthesiol, 2006, 23(4): 305-310.

二级参考文献37

共引文献62

同被引文献25

引证文献3

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部