摘要 基于差热分析原理,提出一种新的铝电解质初晶温度实时测量方法。本文设计的高温熔盐过热度测试仪所测定的铝电解质初晶温度具有较好的重复性和稳定性,其实验测量值与差热分析值相差1.5℃,工业现场测量值与差热分析值误差低于5℃,工业现场多次测量最大偏差为1.8℃。与现有的初晶温度实时测量方法相比,该方法不仅有较高的测量精度,而且简化了操作程序,提高了测量探头的使用寿命。 Based on the rule of differential thermal analysis,a novel method for in-site measuring liquidus temperature of aluminum electrolyte has been suggested.The liquidus temperature data measured by the designed superheat tester for high temperature molten salt have better repeatability and stability,with temperature difference between the experimental and DTA measured values at 1.5 ℃,error between the DTA and in-site measured values less than 5 ℃,and the maximum deviation between the in-site measured liquidus temperatures at 1.8 ℃.Compared with the existing method for determining the liquidus temperature,this method not only has higher measurement accuracy but also can simplify the operation sequence and increase the life of measuring probe.
出处 《武汉科技大学学报》 CAS 北大核心 2015年第2期93-95,共3页 Journal of Wuhan University of Science and Technology
基金 国家科技支撑计划资助项目(2012BAE08B01)
关键词 铝电解 电解质 初晶温度 实时测量 测温装置 aluminum electrolysis electrolyte liquidus temperature in-site measurement tempera-ture measuring device
  • 相关文献

参考文献14

  • 1邱竹贤.铝电解[M].北京:冶金工业出版社,1995.159-161.
  • 2Verstreken P. Bath and liquidus temperature sensor for molten salts[C]//TMS,Light Metals. Pennsyl- vania Warrendale: Minerals, Metal and Materials Soc, 1996 : 437-444.
  • 3Rolseth S, Verstreken P, Kobbeltvedt O. Liquidus temperature determination in molten salts [C]// TMS, Light Metals. Pennsylvania Warrendale: Min- erals, Metal and Materials Soc, 1998 : 359-366.
  • 4Verstreken P, Aegten J T. Sensor arrangement for temperature measurment: US, 005752772A [ P]. 1998-05-11.
  • 5Bohner H O,Arora V,Nasipuri T K. Novel method of messuring the liquidus and bath temperature of HALL-HEROULT cells[C]//TMS, Light Metals. Pennsylvania Warrendale: Minerals, Metal and Ma- terials Soc, 2008 : 315-318.
  • 6冯乃祥,戚喜全,姚恩秀,等.铝电解质熔体温度、初晶温度和过热度的测量装置:中国,ZL200420030787.8[P].2005-05-11.
  • 7Wang X W, Hosler B,Tarcy G. Alcoa STARprobeTM [C]//TMS,Light Metals. Pennsylvania Warrenda- le: Minerals, Metal and Materials Soc, 2011: 483- 489.
  • 8Wang X W, Tarcy G, Batista E, et al. Active pot eontral using Alcoa STARprobeTM [C]//TMS, Light Metals. Pennsylvania Warrendale: Minerals, Metal and Materials Soc,2011:491-496.
  • 9Hosler R B,Wang X W,Bruggeman N,et a[. Molten cryolite bath probe: US, 20050069018A1 [P]. 2005- 03-31.
  • 10Gan Y R,Gao Z S, Zhang A L. Multifunctional sen- sor for use in aluminum celIs[C]//TMS, Light Met- als. Pennsylvania Warrendale Minerals, Metal and Materials Soc, 1995 : 233-240.

二级参考文献10

共引文献51

同被引文献13

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部