摘要
介绍了室内设计参数的选取,分析确定了冷热源的型式,论述了冷热源系统的设计。针对剧院的舞台、观众厅、台仓以及附属的影厅和球幕影院等不同区域,详细阐述了其空调送风、通风及排烟系统的设计。全面阐述了空调水系统的设计,对设计中应注意的消声、隔振等问题进行了总结。
The selection of room paremeters is presented; the cold and heat source are analyzed and determined; and the design of the cold and hem sources system are expounded. The air supply, ventilation, smoke extraction and air conditioning water systems are described for various areas including the auditori- um, secondary video hall, circular screen cinema and stage in details. The problems such as naise reduc- tion and vibration isolation are summarized, which should be given more consideration in the designing.
出处
《建筑节能》
CAS
2015年第4期29-33,共5页
BUILDING ENERGY EFFICIENCY
关键词
剧院
影院
空调
通风
消声
排烟
theatre
cinema
air-conditioning
ventilation
noise reduction
smoke extraction