摘要 研发了一种探测器波形获取电路,实现了1GHz采样率,12 bit采样精度。基于该电路,研制了一套新型γ射线成像位置能量获取系统,用于H8500多阳极位置灵敏光电倍增管的前端位置信号读出与处理。采用信号发生器以及241Am放射源对系统的位置及能量分辨能力进行了测试。结果表明,该系统在对64路阳极信号准确定位的同时也能对γ射线的能量准确测量。 A detector signal acquisition circuit with 1GHz sampling rate and 12 -bit sampling precision has been successfully developed. Based on the circuit, a novel ,γ- ray imaging and position - energy obtainment system is developed, which is used for reading and processing the signal of H8500 position - sensitive photo- multiplier tube (PSPMT) array. The location and energy resolution of the system have tested by using signal generator and 241 Am radiation source. The results indicate that the system can readout both the position of the 64 anode signal and the energy of the γ-rays accurately.
出处 《核电子学与探测技术》 CAS 北大核心 2015年第1期111-114,共4页 Nuclear Electronics & Detection Technology
关键词 γ射线成像 ADC交替采样 DSP FPGA gamma - ray imaging ADC alternating sampling DSP FPGA
  • 相关文献

参考文献11

  • 1陈立宏,李勇平,赵翠兰,袁超.基于MURA编码孔径准直器核辐射成像系统设计[J].核技术,2013,36(8):62-65. 被引量:8
  • 2刘军辉,李道武,章志明,廖燕飞,黄先超,王培林,陈研,贠明凯,丰宝桐,帅磊,王宝义,张天保,魏龙.TOF-PET探测器定时性能初步研究[J].原子能科学技术,2011,45(12):1522-1526. 被引量:2
  • 3HAMAMATSU company: 64 channel multi - anode PMT assembly: DB/OL]. 2011 Hamamatsu PhotonicsK,2011:1 - 5 [2011 - 7 ]. http://www, hamamatsu. eom/resott.,'eea/pdf/ed/: _ H10966 _ :ECI2.
  • 4Popov V,Majewski S,Weisenberger A G,et al. Ana- log readout system with charge division type output [ C]. Nuclear Science Symposium and Medical Ima- ging Conference. San Diego, CA, United states: In- stitute of Electronics Engineers Inc, 2002:1937 - 1940.
  • 5Popov V, Majewski S, Weisenberger A G. Readout e- lectronics for multi - anode photomultiplier tubes with pad matrix anode layout [ C ]. Nuclear Science Sym- posium Conference Record - Nuclear Science Sympo- sium, Medical Imaging Conference. Portland, OR, United states: Institute of Electrical and Electronics Engineers Inc,2003:2156 - 2159.
  • 6Popov V, Majewski S, Benjamin L, et al. A novel readout concept for multi - anode photomultiplier tubes with pad matrix anode layout [ J ]. Nuclear Instruments and Methods in Physics Research Section A:Accelera- tors Spectrometers, Detectors and Associated Equip-ment,2006,567 ( 1 ) : 319 - 322.
  • 7刘蒙,漆玉金,赵翠兰,张雪竹.2×2阵列H8500光电倍增管简化读出电路的设计[J].核技术,2010,33(8):613-618. 被引量:3
  • 8赵翠兰,漆玉金,施亮,金庆,代秋声.多阳极位置灵敏光电倍增管位置读出电路的设计实现[J].原子核物理评论,2010,27(1):63-67. 被引量:8
  • 9Fabbfi A V, Orsolini C, Bennati V P, et al. Dual iso- tope imaging with LaBr3: Ce crystal and H8500 PSPMT [J]. Journal of instrumentation,2013,8(2) : C02022.
  • 10Fabbri A,Notaristedani F,Cencelli V O,Bennati P,et al. 64 - channels low noise FPGA read - out electron- ics for segmented MA - PMT with High Quantum effi- ciency [ J ]. NUCLEAR PHYSICS B - PROCEED- INGS SUPPLEMENTS,2011,2011 (215) :328 - 332.

二级参考文献24

  • 1祁辉荣,王金川,肖国青,郭忠言,詹文龙,丁先利,徐瑚珊,李加兴,孙志宇,胡正国,徐治国,武丽杰,毛瑞士,李文建.平板型光电倍增管64路信号的简化处理[J].核电子学与探测技术,2006,26(4):450-453. 被引量:3
  • 2张猛蛟,漆玉金.高分辨小型伽玛相机位置读出电路研究[J].核技术,2007,30(7):629-632. 被引量:7
  • 3Blankenberg F G. IEEE Eng Med Biol Mag, 2004, 23(4):51-57.
  • 4Lewellen T. Phys Med Biol, 2008, 53: R287-R317.
  • 5Datasheet: Hamamatsu Tube Assembly H8500. http:// www.hamamatsu.com.
  • 6Popov V, Majewski S, Weisenberger A G, et al. IEEE Nucl Sci Symp Conf Rec, 2001, 4:1937-1940.
  • 7Olcott P D, Talcott J A, Habte F, et al. IEEE Nucl Sci, 2005, 51(1): 21-27.
  • 8Popov V, Majewski S, Weisenberger A G, IEEE Nucl Sci Symp Conf Rec, 2003, 3:2156-2159.
  • 9Popov V, Majewski S, Welch B. Nucl Instr Meth, 2006, A567(1): 319-322.
  • 10Wojcik R, Majewski S, Kross B, et al, IEEE Nucl Sci Symp Conf Rec, 2001, 3:1821-1825.

共引文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部