摘要
在坑道内进行γ能谱测量时,其探测结果会受到来自矿井四周的γ射线影响,测量结果不能反映其真实值。为了得到较为真实的值,本文通过MCNP程序对γ能谱的外屏蔽设置在不同材料,厚度及形状的情况下进行模拟,最终得出采用厚度为1 cm铅屏蔽体,外形结构使用圆柱形的屏蔽体;同时采用不同源项设置,得出不同能量段下的透射系数,得出优化结果,为今后矿井下的能谱测定提供定值。
When γspectrometry in the trenches, and the measurement results will be influenced from the γspectrometry around the mine, the measurement results do not reflect its true value.In order to obtain more re-alistic value, in this paper, though the simulation program by MCNP spectrum ofγouter shield settings under different material, thickness and shape, the final results with a thickness of 1 cm lead shielding body and the structure uses a cylindrical shape shield.While using a different source term settings, the transmission coeffi-cient obtained under different energy segments, obtained optimal results, providing value for future mine under Spectrometry.
出处
《核电子学与探测技术》
CAS
北大核心
2015年第2期146-149,共4页
Nuclear Electronics & Detection Technology
基金
国家自然科学基金项目(41074094
51272192)
四川省教育厅自然科学基金重点项目(10ZA118)资助
国家重大专项"深部探测与实验"(SinoProbe)专题
关键词
Γ能谱
MCNP
透射系数
γspectrum
MCNP