摘要
为了实现对凹凸透镜焦距的精准测量,采用彩色数字全息方法进行理论分析和实验验证,取得了与标称值相差1%的数据结果。结果表明,采用数字全息干涉测量方法是可靠的,可以获得与用透镜标称值重构相同的效果。该研究对数字全息波前的重建有帮助。
In order to measure the focal length of a concave and convex lens accurately,theoretical analysis and experimental verification were carried out based on the color digital holographic method,and the measurement difference relative to the nominal value was 1%. The results indicate the digital holographic interferometry is reliable and the same effect as that of lens nominal value reconstruction can be obtained. The result is helpful for digital holographic wavefront reconstruction.
出处
《激光技术》
CAS
CSCD
北大核心
2015年第4期562-565,共4页
Laser Technology
基金
云南省人培基金资助项目(KKSY201407082)
云南省教育厅面上基金资助项目(KKJA201207008)
云南省教育厅卓越教师特殊支持计划资助项目(1096826901)
关键词
全息
彩色数字全息
透镜焦距测量
干涉
多波长
holography
color digital holography
lens focal length measurement
interference
multi wavelength