摘要 在使用热气旁通技术进行能量调节的工业制冷系统中,热气旁通阀是该系统的核心部件,其正确的选型直接决定着系统运行的可靠性及稳定性。针对热气旁通阀选型方法的问题,本文在详细分析热气旁通系统特点的基础上,推荐采用膨胀系数法作为阀门的选型方法,并以实例详细说明选型步骤以及需要注意的问题。 Hot-gas bypass valve is the core component of the industrial refrigeration system which uses hot-gas bypass technology to adjust energy. The selection of hot-gas bypass valve determines the operation reliability and stability of the system. In order to solve the issues of hot-gas bypass valve selection method, the expansion coefficient meth- od is recommended as the selection method of valve based on the detailed analysis of the characteristics of the hot-gas bypass system. Combined with examples, the selection steps and the issues which need attention are described in detail.
出处 《制冷与空调》 2015年第6期19-23,共5页 Refrigeration and Air-Conditioning
关键词 工业制冷系统 热气旁通阀 阻塞紊流 阀门流量系数 调节阀 industrial refrigeration system hot-gas bypass valve chocked turbulentflow valve flow coefficient control valve
  • 相关文献

参考文献3

二级参考文献11

  • 1张兆顺 崔贵香.流体力学[M].北京:清华大学出版社,2001..
  • 2ASHRAE HANDBOOK COMMITTEE.2006 ASHRAE HANDBOOK/REFRIGERAION.USA:ASHRAE Inc,2006.
  • 3费希尔控制设备有限公司.《控制阀手册》,第三版.2010.
  • 4吴国熙.调节阀使用与维修[M].北京:化学工业出版社,2001.
  • 5林秋鸿.ISA调节阀手册[M].2版.北京:化学工业出版社,1984.
  • 6奚文群,谢海维.调节阀口径计算指南[M].兰州:化学工业部自控技术中心站,1991.
  • 7施俊良.调节阀的选择[M].北京:中国建筑工业出版社,1966.
  • 8上海工业自动化仪表研究所,上海仪器仪表自控系统检验测试所.GB/T4213--2008气动调节阀[s].北京:中国标准出版社,2008.
  • 9王群增,郑秋萍,王燕,等.GB/T17213.2-2005工业过程控制阀第2-1部分:流通能力安装条件下流体流量的计算公式[S].北京:中国标准出版社,2006.
  • 10蔡永生.氨液再循环系统中氨泵最小倒灌高度的计算与分析[J].制冷与空调,2009,9(3):98-101. 被引量:3

共引文献13

同被引文献9

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部