期刊文献+

核电站建设阶段堆外核测仪表典型故障诊断与质量管控 被引量:6

The Typical Failure Diagnosis and Quality Control on the Ex-core measuring Instrumentation During the Construction Phase of nuclear Power Plant
下载PDF
导出
摘要 本文结合国内核电站建设阶段堆外核仪表系统(RPN)典型故障诊断,分析核仪表故障根本原因,并且阐述了核电站建设阶段核仪表系统全过程质量管控措施。本文对同类型核电站在核仪表设计、制造、调试、维修等方面的工作具有一定经验反馈价值。 Combining the typical failure diagnosis of ex-core nuclear instrumentation system(RPN) in our country, this paper analyses the root cause of nuclear instrumentation's failure and introduces the whole process of quality control on the nuclear instrumentation system during the construction phase of nuclear power plant. Meanwhile the experience is of great value in the nuclear instrumentation's design, manufacture, commission and maintenance for other nuclear power plants of same type.
出处 《自动化博览》 2015年第7期56-58,共3页 Automation Panorama1
关键词 核仪表 故障诊断 质量管控 Nuclear instrumentation Failure diagnosis Quality control