期刊文献+

木材-T型钢填板螺栓连接节点耐火极限试验 被引量:10

Experiment for fire endurance of bolted timber connection nodes with slotted-in T-shaped steel plate
下载PDF
导出
摘要 为了研究不同持荷水平和不同表面处理措施对木结构节点耐火极限的影响,进行了木材-T型钢填板螺栓连接节点试验.结果表明,木材-T型钢填板螺栓连接节点试件的最终破坏形式为木材在螺栓孔处撕裂,卸载后除梁顶螺栓处有较大纵向裂缝,其余裂缝基本闭合.与持荷水平为10%的试件相比,持荷水平为20%和30%的试件耐火极限分别降低了17.1%和52.1%,持荷水平越高,对耐火极限降低的相对影响越大.表面采用防火涂料处理后,持荷水平为30%的试件耐火极限提高约85%.试件同一横截面、相同埋置深度处同材质材料的温度是相同的,但钢材温度高于木材. In order to study the effect of different sustained load levels and different fire-retardant treatments on the fire endurance of timber structure nodes, the experiments for the bolted timber connection nodes with slotted-in T-shaped steel plate were carried out. The results show that the final failure mode for the specimens of bolted timber connection nodes with slotted-in T-shaped steel plate is the tearing-out failure of timber around bolt holes. After unloading, the cracks basically close except for the longitudinal cracks around the bolt holes in the upper part of the beam. Compared with the specimen with the sustained load level of 10%, the fire endurance of the specimens with the sustained load levels of 20% and 30% decreases by 17. 1% and 52. 1%, respectively. The higher the sustained load levels are, the larger the effect of sustained load level on the decrease degree of the fire endurance is. The fire endurance of the specimen with the sustained load level of 30% will increase by 85% after adopting the flame-retardant treatment on the surface. The temperatures of the same material with the same cross-section and embedment depth are the same, while the temperature of steel is higher than that of timber.
出处 《沈阳工业大学学报》 EI CAS 北大核心 2015年第5期594-600,共7页 Journal of Shenyang University of Technology
基金 国家自然科学基金资助项目(51178115) 江苏省自然科学基金资助项目(BK2012239)
关键词 T型钢填板 木结构螺栓连接 木结构 火灾试验 耐火极限 温度场 持荷水平 防火涂料处理 slotted-in T-shaped steel plate bolted timber connection timber structure fire test fire endurance temperature field load level fire-retardant treatment
  • 相关文献

参考文献10

二级参考文献75

  • 1YOUNG S, CLANCY P. Compression mechanical properties of wood at temperatures simulating fire condltlon[J]. Fire and Materials, 2001, 25(2) :83-93.
  • 2LIE T. A method for assessing the fire resistance of laminated timber beams and columns[J]. Canadian Journal of Civil Engineering, 1977, 4(2) : 161-169.
  • 3National Building Code of Canada. Canadian Commission on Building and Fire Codes[S]. Ottawa, Ontario, 1995.
  • 4Technical Report 10, Calculating the fire resistance of exposed wood members[R]. AF & PA, 2003.
  • 5EN 1995-1-2 : 2004, Eurocode 5 : Design of timber structures [ S ]. Part 1-2: general-structural fire design.
  • 6WHITE R. Fire resistance of exposed wood member[C]//Wood & fire safety, Proceedings of 5th International Scientific Conference, 2004: 337-344.
  • 7BABRAUSKAS V. Charring rate of wood as a tool for fire investigations [ J ]. Fire Safety Journal, 2005,40 (6) : 528-554.
  • 8许清风,徐强,李向民,等.基于炭化速度的木结构防火设计方法研究[R].上海市建筑科学研究院,2009.
  • 9GB50005-2003木结构设计规范[S].北京:中国建筑工业出版社,2006.
  • 10Buchanan A. Fire resistance of solid timber structures [ R]. New Zealand: New Zealand Department of Civil and Natural Resources Engineering, Uinversity of Canterbury, 2005.

共引文献78

同被引文献193

引证文献10

二级引证文献131

相关作者