摘要 针对水电机组启停频繁的特点,对小湾电站开机控制规律进行了深入探讨。研究了各种参数及机组开机规律,对机组开机流程启动源进行了完善并提出优化措施,对部分自动化元器件加入冗余判断,提高了流程判断测点的科学性和机组开机条件判断及过程的可靠性,机组自动开机成功率不断提高。 The starting and shut-down of hydro-generators in Xiaowan Hydropower Station is frequent. The laws of starting and shut-down controls for the hydro-generators in Xiaowan Hydropower Station are studied. By studying the parameters and laws of starting and shut-down, the starting process sources are improved and optimized and some automation components are added with redundancy judgment. These optimizations improve the scientific judgment of starting and shut-down process and the reliability of starting condition judgment, and continuously improve the success rate of unit automatic starting.
作者 陈团军
出处 《水力发电》 北大核心 2015年第10期18-20,共3页 Water Power
关键词 机组自动开机 开机逻辑条件 优化措施 小湾水电站 automatic starting of unit starting logic condition optimization Xiaowan Hydropower Station
  • 相关文献

参考文献3

  • 1郭文涛.水轮发电机组自动开机优化措施[C]//2012年江西省电机工程学会年会论文集.南昌:江西省电机工程学会,2012:184-186.
  • 2李春露,杨建彬,陈映喜.小湾电厂无人值班整改1-6号机组监控侧逻辑实施配合方案[R].大理:华能小湾水电厂,2014.
  • 3卢凤磊,柯文俊,等.小湾电厂异常处理汇编手册[R].大理:华能小湾水电厂,2013.