期刊文献+

3D-SPACE序列磁共振胰胆管显影诊断胆囊及胆总管结石 被引量:21

Magnetic resonance cholangiopancreatography of three-dimensional sampling perfection with application optimized contrasts sequence in diagnosis of gallstone and common bile duct stones
下载PDF
导出
摘要 目的比较三维可变翻转角的快速自旋回波(3D-SPACE)与三维传统快速自旋回波(3D-TSE)及二维快速自旋回波(2D-TSE)序列磁共振胰胆管显影(MRCP)用于显示胆囊及胆总管结石的图像质量。方法采用呼吸导航的3D-SPACE序列和传统3D-TSE序列及屏气采集的2D-TSE对10名健康志愿者(对照组)和22例胆道结石患者(患者组)行MRCP,比较3种成像方法的图像采集时间、胆总管CNR、胰胆管影像质量、及对结石的显示情况。结果在患者组及对照组中,3D-SPACE胆总管CNR均明显高于传统2D-TSE、3D-TSE序列(P均<0.05);3D-SPACE序列图像质量评分、运动伪影、胆总管、左右肝内胆管、主胰管评分均明显高于2D-TSE、3D-TSE序列(P均<0.05);3D-SPACE序列影像采集时间均较传统3D-TSE序列减少,患者组减少(20.90±0.21)%,对照组减少(23.09±0.12)%。2D-TSE序列用时最短,SPACE序列原始像对胆囊及胆总管结石显示最优。结论相比于2D-TSE-MRCP、3D-TSE-MRCP序列,3D-SPACEMRCP影像质量更好,其原始影像更适用于显示胆囊和胆管结石,但图像采集时间长于2D-TSE。 Objective To evaluate the image quality of magnetic resonance cholangiopancreatography,(MRCP)displaying the gallstone and common bile duct stones(CDS)using three-dimensional sampling perfection with application optimized contrasts(3D-SPACE),three-dimensional turbo-spin-echo(3D-TSE),two-dimensional turbo-spin-echo(2D-TSE)sequences.Methods The navigator-triggered 3D-SPACE sequence,navigator-triggered 3D-TSE sequence and breath-hold2D-TSE sequence were applied to 10volunteer(control group)and 22 patients with gallstone and(or)CDS(patient group),and then the CNR of common bile duct,image quality,scanning time and the ability of displaying the stones were compared.Results In patient group and control group,the CNR of common bile duct on 3D-SPACE-MRCP were significantly higher than those of 3D-TSE and 2D-TSE sequences(all P〈0.05).The scores of image quality,motion artifacts,common bile duct,the left hepatic,right hepatic and the main pancreatic duct on 3D-SPACE-MRCP were better than those on 3D-TSE-MRCP and 2D-TSE-MRCP(all P〈0.05).Comparing with 3D-TSE-MRCP,image acquisition time of 3DSPACE-MRCP was shorted(20.90±0.21)%in patient group and(23.09±0.12)% in control group.The 2D-TSE sequence consume the minimum time.Primitive images of 3D-SPACE sequence do the best in displaying the gallstone and CDS.Conclusion Although consuming more time then 2D-TSE sequence,but compared with 3D-TSE-MRCP and 2DTSE-MRCP,3D-SPACE-MRCP can provide higher quality imaging,and primitive images is more suitable for clinical application on the gallstone and CDS.
出处 《中国医学影像技术》 CSCD 北大核心 2015年第10期1582-1586,共5页 Chinese Journal of Medical Imaging Technology
关键词 胰胆管造影术 磁共振 可变翻转角的快速自旋回波 自旋回波 Cholangiopancreatography magnetic resonance Sampling perfection with application optimized contrasts Turbo-spin-echo
  • 相关文献

参考文献12

  • 1Limanond P, Raman SS, Ghobrial RM, et al. The utility of MRCP in preoperative mapping of biliary anatomy in adult-to-a- dult living related liver transplant donors. J MagnReson Ima- ging, 2004,19(2) :209-215.
  • 2Takeshi Nakaura MD, Masafumi Kidoh MD, Nstsuki Maruyama MD, et al. Usefulness of the SPACE pulse sequence at 1.5T MR eholangiography:Comparison of image qualityand image acquisi tion time with conventional 3D-TSE sequence. J Magn Reson Im- aging, 2013,38(5) : 1014-1019.
  • 3Morita S, Ueno E, Suzuki K, et al. Navigator-triggered prospec tive acquisition correction (PACE) technique vs. conventional re- spiratory-triggered technique for free-breathing 3DMRCP: An in- itial prospective comparative study using healthy volunteers. J Magn Reson Imaging, 2008,28(3) :673-675.
  • 4Zhang J, Israel GM, Hecht EM, et al. Isotropic 3D T2-weighted MR cholangiopancreatograply with parallel imaging: Feasibility study. AIR, 2006,187(6):1564-1570.
  • 5Nandalur KR, Hussain HK, Weadock WJ. et al. Possible biliary disease: Diagnostic performance of high-spatial-resolution iso- tropic 3D T2-weighted MRCP. Radiology, 2008, 249 (3): 883 890.
  • 6孙岩,吴雪,谢萍,郝跃峰,胡丹,刘可夫.磁共振3D-SPACE、3D-TrueFISP、2D-FSE-PD序列膝关节软骨成像的比较研究[J].实用放射学杂志,2015,31(1):131-135. 被引量:16
  • 7杜春华,吴飞云,祝因苏,张伟,刘波,杨正强.磁共振3D-SPACE序列与3D-CISS序列对Ⅴ~Ⅷ颅神经成像的对照性研究[J].临床放射学杂志,2012,31(12):1699-1702. 被引量:21
  • 8夏加林,万仁志,陈建新,马明,陈振.1.5T磁共振3D-SPACE序列与3D-TSERT序列在MRCP成像中的应用对比[J].医疗卫生装备,2014,35(2):83-85. 被引量:9
  • 9陈文萍,宗敏,陈其春,王德杭.磁共振3D-TSE(SPACE)序列在评估健康受试者踝关节解剖结构的应用研究[J].实用放射学杂志,2012,28(4):580-584. 被引量:13
  • 10Arizono S, Soda H, Maetano YS, et al. High spatial resolution 3D MR cholangiography with high sampling efficiency technique (SPACE) : Comparison of 3T vs. 1. ST. Eur J Radiol, 2010, 73 (1) :114-118.

二级参考文献62

  • 1Mugler JP III, Kiefer B, Brookeman JR. Three-dimensional T2-weighted imaging of the brain using very long spin-echo trains In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: ISMRM, 2000:1630.
  • 2Mugler JP Ⅲ, Meyer H, Kiefer B. Practical implementation of optimized tissue specific prescribed signal evolutions for improved turbo-Spin Echo imaging. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: ISMRM, 2003: 203.
  • 3Morita S, Ueno E, Masukawa A, et al. SPACE vs. 3D TSE MRCP at 1.5T MRI with Regard to Difference of Echo Spacing. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: ISMRM, 2009: 4018.
  • 4Park J, Mugler JP III, Horger W, et al. Optimized T1- weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains: Application to whole-brain imaging. Magn Reson Med, 2007, 58(5): 982-992.
  • 5Li GB, Sauerbier C, Paul D, et al. Verse-Space. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley. Calif: ISMRM, 2010: 3036.
  • 6Mugler JP III, Brookeman JR. Efficient spatially-selective single-slab 3D turbo-spin-echo imaging. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif:ISMRM, 2004: 695.
  • 7Li GB, Paul D, Zhang WJ, et al. Multi-slab SPACE. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: ISMRM, 2010: 3037.
  • 8Li GB, Nittka M, Hollenbach HP, et al. The shifted radial reordering for intermediate TE imaging in 3D long echo train acquisition. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: ISMRM, 2009: 2623.
  • 9Priatna A, Foster G, Xu J, et al. NATIVE SPACE angiography with MTC and fat saturation pulses. In: Proceedings of file International Society for Magnetic Resonance in Medicine. Berkeley, Calif:ISMRM, 2009: 1878.
  • 10Xu J, Weale P, Gerhard L, et al. A novel non-contrast MR angiography technique using triggered non-selective refocused SPACE for improved spatial resolution and speed. In: Proceedings of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif:ISMRM, 2008:730.

共引文献100