期刊文献+

腔内心电图用于锁骨下静脉置管定位的临床研究 被引量:3

Clinical study of intracavitary ECG used for subclavian vein catheterization positioning
下载PDF
导出
摘要 目的探讨腔内心电图用于锁骨下静脉置管定位的可行性与可靠性。方法将60例择期非心脏停跳下冠状动脉旁路移植术病例随机分到观察组和对照组,每组各30例。观察组用腔内心电图确定导管置入深度,对照组用L=H/10-2(cm)公式计算值确定导管置入深度。导管最终位置通过胸部X线检查确定。结果观察组0例(0%)和对照组例18(60%)导管置入位置异常(过深12例、过浅1例、误入右颈内静脉5例)(P<0.05)。导管置入深度,观察组(12.1±1.1)cm,对照组(14.1±1.4)cm,两者比较差异有统计学意义(P<0.05)。穿刺和置管次数、时间,两组间比较差异无统计学意义(P>0.05)。术中导管使用异常发生率,两组间比较差异有统计学意义(P<0.05)。结论腔内心电图引导右锁骨下静脉置管可靠并且可行,可作为一项常规技术应用于临床。 [Objective ] To investigate the feasibility and reliability of the intracayitary ECG for subclavian vein catheterization. [ Methods ] 60 patients undergoing elective non-cardiac-arrest coronary artery bypass grafting were randomly divided into observation group and control group, 30 cases in each group. The catheter insertion depth was determined by intracayitary ECG in observation group and by the calculation value with L=H/10-2 (cm) formula in control group. The final position of the catheter was determined by chest X-ray examination. [Results] The abnormal catheter position was found in 18 cases (60%) of control group (12 cases of too deep, 1 cases of too shallow and 5 cases of right internal jugular vein catheterization) and 0 case (0%) of observing group (P 〈 0.05). Catheter inser- tion depth was (12.1 ± 1.1) cm in the observation group and (14.1 ± 1.4) cm in the control group (P 〈 0.05). The difference comparing between two groups were not significant with the number and the time of puncture and catheterization (P 〉 0.05). The rate of Intraoperative abnormal use of catheter between two groups had significant difference (P 〈 0.05). [ Conclusion ] Intracavitary ECG lead right subclavian vein catheterization is reliable and feasible, and can be used as a routine technique in clinical application.
出处 《中国现代医学杂志》 CAS 北大核心 2015年第31期92-95,共4页 China Journal of Modern Medicine
关键词 锁骨下静脉 置管 腔内心电图 定位 subclavian vein catheterization intracavitary electrocardiogram positioning
  • 相关文献

参考文献3

二级参考文献30

  • 1万诚,应雪琼,胡小琴,林心怡,丁玲利.经外周中心静脉置管术在危重新生儿中的应用[J].现代实用医学,2006,18(4):255-256. 被引量:4
  • 2杨海燕.中心静脉导管并发症的防治进展[J].上海护理,2007,7(3):56-59. 被引量:20
  • 3Peres P W. Positioning central venous catheters- a prospective survey[ J ]. Anaesth Intensive Caro, 1990,18 ( 4 ) : 536- 539.
  • 4Thomas M, Vesely M D. Central venous catheter tip position : a continuing controversy [ J ]. J Vasc Interv Radiol, 2003,14 (5) :527-534.
  • 5Darling J C, Newell S J, Mohamdee O,et al. Central venous catheter tip in the right atrium :a risk factor for neonatal cardiac tamponade [ J ]. J Perinatol,2001,21 (7) :461-464.
  • 6Eerola R, Kaukinen L, Kaukinen S, et al. Analysis of 13 800 subclavcian vein catheterizations [ J ]. Acta Anaesthesiol Stand. 1985,29 ( 2 ) : 193 -197.
  • 7Marouche A. EKG-Lagekontrolle zentralvenoser Katheter uber den Seldinger-Fuhrungsdratt. Klinische und okonomische Aspekte[J]. Anasthesiol Intensivemed Notfallmed Schmerzther, 1998,33(2) :114-117.
  • 8Hassan N, Halanski M, Wincek J, et al. Blood management in pe- diatric spinal deformity surgery: review of a 2-year experience. Intensive Care Med,2011,51:2133-2141.
  • 9Hobaika AB, Femandes ML, Cancado CL, et al. Severe hemody- namic instability during the use of isoflurane in a patient with id- iopathic scoliosis. Rev Bras Anestesiol, 2007, 57:177-181.
  • 10Lustik SJ, Papadakos PJ, Jackman KV, et al. Nicardipine versus nitroprusside for deliberate hypotension during idiopathic scoliosis repair. J Clin Anesth,2004,16:25-33.

共引文献23

同被引文献16

引证文献3

二级引证文献22