水凝胶灭火剂对装饰装修材料烟密度的影响 被引量:4

Effect of Hydrogel Fire-extinguishing Agent on Smoke Density of Decoration Materials
下载PDF
导出
摘要 选取了4种普通的装饰装修材料——化纤窗帘、纯棉窗帘、聚苯乙烯泡沫板、尼龙地毯,采用SCY-1型建筑材料烟密度测定仪测量各种材料燃烧过程中烟密度的变化,并通过对比试验考察了在材料中加入水凝胶灭火剂后对各种材料烟密度的影响。结果表明:同种材料,加入水凝胶灭火剂后最大烟密度、总产烟量和烟密度等级均有增加,但加入水凝胶灭火剂的材料开始产烟的时间比未加入水凝胶灭火剂的时间延迟;4种装饰装修材料中,聚苯乙烯泡沫板的最大烟密度、总产烟量和烟密度等级最大。 This study measures the smoke density changes during combustion process of four selected com- mon decoration materials including chemical fiber curtain, pure cotton curtain, polystyrene foam board and nylon carpet by adopting the building materials smoke density tester SCY-1. Also the study conducts a comparison experiment to investigate the influence of adding the hydrogel fire-extinguishing agent to the materials on smoke density of the four materials. The results show that after adding the fire-extinguishing agent, the maximum smoke density(MSD), total production of smoke and smoke density rating(SDR)all in- crease for each material with a time delay of the smoke emerging ~ among the four materials,the above indi- cators of the polystyrene foam board are the highest.
作者 王平
出处 《安全与环境工程》 CAS 2015年第6期125-128,共4页 Safety and Environmental Engineering
关键词 水凝胶灭火剂 装饰装修材料 烟密度 对比试验 hydrogel fire-extinguishing agent decoration material smoke density comparison experiment
  • 相关文献

参考文献20

二级参考文献72

  • 1刘道强,徐志胜,王飞跃.建筑材料火灾烟气减光性能的试验研究[J].中国安全科学学报,2005,15(3):53-56. 被引量:3
  • 2卢国建,刘松林,彭小芹.木材的燃烧性能研究——锥形量热计法[J].消防科学与技术,2005,24(4):414-418. 被引量:26
  • 3王小红,廖剑波,祝华国.建筑幕墙用铝塑复合板的火灾危险性研究[J].中国建材科技,2010,19(5):41-46. 被引量:4
  • 4Chuang, T. H. , C.K. Chren. The application of expandable graphite as a flame retardant and smoke-suppressing additive for ethylene-propylene-diene terpolymer[J]. Journal of Polymer Research, 1997, 4(3) : 153--158.
  • 5Quintiere,J. G. A theoretical basis for flammability properties [J]. FireMater, 2006,30: 175--214.
  • 6GB/T18627-1999,建筑材料燃烧或分解的烟密度实验方法[S].
  • 7[1]Levin B C,et al.Further development of the n-gas mathematical model.American Chemical Society,1995,Chapter20
  • 8[2]Gottuk D T,et al.Carbon monoxide production in compartment fires.Journal of Fire Protection Engineering.1992,4:133
  • 9[3]Debanne S M,et al.The importance of carbon monoxide in the tox-icity of fire atmospheres.Fire Hazard and Fire Risk Assessment,ASTM STP1150,1992,9
  • 10[4]Nelson G L.Carbon monoxide and fire toxicity:A review and anal-ysis of recent work.Fire Technology,1998,34(1):39

共引文献57

同被引文献52

引证文献4

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部