摘要
涟钢30 000m3/h制氧机组在运行过程中,发生一起换热器水侧堵塞事故,对其堵塞的原因进行了分析,并采取相应处理措施,解决了换热器堵塞问题。
During run of 30 000 m3/h oxygen generation unit of Valin Lysteel , heat exchangers water passage are blocked trouble,analysis of the causes for the blocking ,and take corresponding measures ,solve the trouble of heat exchangers block-age.
出处
《低温与特气》
CAS
2015年第5期53-54,共2页
Low Temperature and Specialty Gases
关键词
填料
堵塞
换热器
packed
blocking
heat exchanger