摘要 在小型实验装置上,配制模拟放射性废水,采用复合反渗透膜对废水中的铯进行去除实验,研究不同条件下铯的去除效果。结果表明:废水p H、进水压力和回收率等因素会影响反渗透对铯的去除效果,其中p H的影响最为显著。随着进水压力的增大、元件回收率的降低和进水p H的升高,反渗透对铯的去除率提高。通过控制合适的条件,可将反渗透对铯的去除率保持在90%以上。 Experiments of removing cesium from simulated radioactive wastewater by composite reverse osmosis membrane on a pilot reverse osmosis equipment. Cesium rejection performance of reverse osmosis technology under different conditions was researched. Results revealed that cesium rejection ratio would be affected by pH of wastewater, inlet pressure and element recovery. The most important influence factor was pH of wastewater. With the increasing of inlet pressure and pH or the decreasing of recovery, the rejection ratio would be improved. The rejection ratio could be maintained above 90 percent by controlling appropriate conditions.
机构地区 海军工程大学 [
出处 《广东化工》 CAS 2015年第23期153-154,共2页 Guangdong Chemical Industry
关键词 反渗透 放射性废液 去除率 reverse osmosis radioactive wastewater cesium rejection ratio
  • 相关文献

参考文献5

  • 1孔劲松,田沿杰.反渗透对模拟放射性废水中钴的截留性能研究[J].核动力工程,2012,33(1):101-103. 被引量:6
  • 2孔劲松,王晓伟.反渗透对模拟放射性废水中锰的截留性能研究[J].核动力工程,2012,33(6):124-126. 被引量:3
  • 3Berrin Tansel, John Sager, Tony Rector, et al. Significance of hydrated radius and hydration shells on ionic permeability during nanofiltration in dead and cross flow modes[J]. Separation and Purification Technology, 2006, 51 : 40-47.
  • 4Sancho M, Areal J M, Verdu G, et al. Ultrafiltration and reverse osmosis performance in the treatment of radioimmunoassay liquid wastes[J]. Desalination, 2006, 201: 207-215.
  • 5Paul D R. Reformulation of the solution-diffusion theory of reverse osmosis[J]. Joumal ofMembraneScience, 2004, 241: 371-386.

二级参考文献4

共引文献6

同被引文献17

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部