摘要 针对人体通信技术在可穿戴设备中应用缺少准确的理论分析方法的问题,提出了一种等效电路分析方法。将人体组织的通信信道等效成可解析的阻抗电路,通过对电路的分析计算得到人体通信的信道增益。在此基础上,利用有限元仿真软件HFSS建立了人体通信模型,仿真结果与等效电路分析方法计算的信道增益差距小于1 d B。仿真分析表明:该分析方法能够准确地描述可穿戴设备中人体通信信道的特性,完善了可穿戴设备中人体通信技术的分析方法。 Aiming at problem that application of human-body communication technology in wearable devices lack of accurate theoretical analysis method,an equivalent circuit analysis method is proposed. Human tissue 'communication channel is seen as an analysable impedance circuit,channel gain of human-body communication is obtained by analyzing and calculating on circuit. On this basis,human-body communication model is established by using FEM simulation software HFSS,difference of channel gain between equivalent circuit analysis method and simulation results is less than 1 d B. Simulation results show that the analysis method can accurately represent characteristic of human-body 's communication channel in wearable device and improves analysis method of human-body communication technology for wearable device.
出处 《传感器与微系统》 CSCD 2015年第12期36-38,42,共4页 Transducer and Microsystem Technologies
关键词 可穿戴设备 人体通信 等效电路模型分析方法 wearable device human-body communication equivalent circuit model analysis method
  • 相关文献

参考文献8

  • 1Zimmerman T G. Personal area networks: Near-field intrabody communication [ J ]. IBM System, 1996,35:609 -617.
  • 2Shasha i,, Fengye H, Guofeng L. Advances and challenges in body area network [ J]. Communications in Computer and Infor- mat/on Scieme ,20! 1,226:58 -65.
  • 3Hachisuka K, Nakata A, Takeda T. Development of wearable intra-body conmmnication devices[ J]. Sensors and Actuators A: Physical ,2003,105 : 109 --115.
  • 4Tronstad C,Johnsen G K,Johnsen C, et a|. A study: on electrode gels for skin conductance measurements [ J ]. Physiol Measure- ment,2010,31 (10) : 1395 --1410.
  • 5阮方鸣,Tomasz Dlugosz,高攸纲.计算人体生物电阻抗的柱体模型算法[J].电子学报,2010,38(2):469-472. 被引量:7
  • 6S waminathan M, Cabrera F S, Pujol J S, et al. Muhi-path model and sensitivity analysis for galvanic coupled intra-body communi- cation through layered tissue [ J ]. IEEE Transactions on Biomed Circuits and Systems,2015,99:1.
  • 7Wegmueller M S, Oberle M, Felber N, et al. Signal transmission by galvanic coupling through the human body[ J]. IEEE Transac- tions on Instrument ,2010,59 (4) :963 --969.
  • 8Cho N, Yoo ], Song S J, et al. The human body characteristics as a signal transmission medium for intrabody communication [ J ]. IEEE Transactions on Microwave Theory anc[ Techniques,2007, 55 : 1080 --1086.

二级参考文献13

  • 1CRAWFORD M L. Generation of standard EM field using TEM transmission cell[ J]. IEEE Transactions on Electromagnetic Compatibility, 1974,16(4) : 189 - 195.
  • 2DLUGOSZ T, TRZASKA H. Proximity effects in EMF measurements and standards [ A ]. ⅩⅩⅧth General Assembly of International Union of Radio Science[ C]. New Delhi: International Union of Radio Science, CD Proceedings, 2005.
  • 3TRZASKA H. Calibration of directional antennas and lirnitations in their use[ J]. IEEE, Transactions on Instrumentation and Measurements, 2000,49(5) : 1112 - 1116.
  • 4DLUGOSZ T, TRZASKA H. Mutual interactions in bioelectromagnetics[ J]. The Environmentalist, 2007,27(4) :403 - 409.
  • 5DLUGOSZ T, TRZASKA H. Mutual interactions in EMF dosimetry [ A ]. Proceedings of the International Conference and COST 281 Workshop on Emerging EMF-Technologies, Potential Sensitive Group and Health[ C]. Graz: Institute of Clinical Engineering of Graz University of Technology, CD Proceeding, 2006.
  • 6Italian National Research Council. An Intemet resource for calculation of "Dielectric Properties of Body Tissues in the frequency range 10Hz- 100GHz"[DB/OL] .http://niremf.ifac. cnr. it/fissprop/, 2008-05-20.
  • 7LEBLANC D, HATCHER D, POST R D. Finite-Difference Time-Domain Front-End Utility [M]. Texas:Brooks Airforce Base,2000.
  • 8LIEDTKE R J. Principles of bioelectrical impedance analysis DB/OL]. http://www. rjlsystems. com/docs/bia info/principles/, 1997-04-10.
  • 9KANAI H, CHATTERJEE I, GANDHI O P. Human body impedance for electromagnetic hazard analysis in the VLF to MF band [ J ]. IEEE Transactions on Microwave Theory and Techniques, 1984,32( 8 ) : 763 - 772.
  • 10LIEDTKE R J. The fundamentals of bioelectrical impedance analysis [ DB/OL ]. http://www. rjlsystems. com/docs/bia_ info/fundamentals/fundamentals. pdf, 1998-02-16.

共引文献6

同被引文献23

  • 1Zimmerman TG. Personal intra-body communication area [D]. networks ( PAN ) : Near-field Cambridge : Massachusetts Institute of Technology, 1995.
  • 2IEEE 802. 15;6 - 2012, IEEE Standard for Local and Metropolitan Area Networks - Part 15.6: Wireless Body Area Networks[ S ].
  • 3Kulkami VV, Lee J, Zhou J, et al. A reference-less injection- locked clock-recovery scheme for multilevel-signaling-based wideband BCC receivers[ J]. IEEE Trans Microw Theory, 201,1, 62(9) : 1856 - 1866.
  • 4Cho H, Bae J, Yoo HJ. A 37.5 mu W body channel communication wake-up receiver with injection-locking ring oscillator for wireless body area network [ J ]. IEEE Trans Circuits-I, 2013, 60(5): 1200-1208.
  • 5Baldus H, Corroy S, Fazzi A, et al. Human-centric connectivity enabled by body-coupled communications [ J ]. IEEE Commun Mag, 2009, 47(6): 172-178.
  • 6Seyedi M, Kibret B, Lai DTH, et al. A survey on intrabody communications for body area network applications [ J]. IEEE Trans Biomed Eng, 2013, 60 (8) : 2067 - 2079.
  • 7Cho N, You J, Song SJ,et al. The human body characteristics as a signal transmission medium for intrabody communication [ J ]. IEEE Trans Mierow Theory, 2007, 55 (5) : 1080 - 1086.
  • 8Callejon MA, Naranjo-Hernandez D, Reina-Tosina J, et al. A comprehensive study into intrabody communication measurements [ J]. IEEE Trans Instrum Meas, 2013, 62 (9) : 2446 - 2455.
  • 9Anderson GS, Sodini CG. Body coupled communication: the channel and implantable sensors[ C ] //2013 IEEE International Conference on Body Sensor Networks. Cambridge: IEEE, 2013 : 1-5.
  • 10Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: Measurements in the frequency range 10 Hz to 20 GHz[J]. PhysMed Biol, 1996, 41(11): 2251 -2269.

引证文献5

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部