摘要 针对油田污水回用于热采锅炉导致注汽管道内壁盐沉积的问题,选取新疆油田某区注汽管道内积盐为试样,采用SEM,XRD,EDS,XPS等手段对积盐进行表征。探讨了注汽管道内积盐成因,并提出了防止和缓解积盐的措施。表征结果显示,注汽管道内壁附有的积盐呈规则块状,剖面平滑致密,外表面粗糙,可见大量针状物,主要组成为Na_2Si_2O_5和少量Na_2CO_3。实验结果表明,注汽锅炉给水中高浓度的NaCl不会沉积在管道内壁,积盐是进水中硅酸、碳酸氢钠、碳酸钠在高温、高压(12.6 MPa,486℃)条件下长时间作用形成的。增强蒸汽管道的保温措施,并控制回用污水中的硅含量可有效缓解注汽管道内盐沉积形成。 When oilfield sewage was reused in thermal recovery boiler, salt deposition formed in steam pipeline in the Xinjiang oilfield. The salt deposition was characterized by means of SEM, XRD, EDS and XPS. The results showed that the salt deposition in steam pipeline was regular block shape with smooth dense section and rough surface, and its major components were Na2Si2O5 and a small amount ofNa2CO3, which formed due to the interaction of silicic acid, sodium bicarbonate and sodium carbonate in reused sewage under high temperature and high pressure(12.6 MPa and 486 ℃), and high concentration sodium chloride in the reused sewage would not deposit in the pipeline. The formation of the salt deposition could be relieved through improving the heat preservation of the steam pipeline and controlling the silicon content in the reused sewage.
出处 《石油化工》 CAS CSCD 北大核心 2015年第12期1524-1528,共5页 Petrochemical Technology
基金 MPE-3重油高效集输关键技术研究项目(60058-00-0000-CA-002)
关键词 油田污水回用 热采锅炉 注汽管道 盐沉积 oilfieldsewagereuse steam-injectionboiler steam pipeline salt deposition
  • 相关文献

参考文献21

  • 1Tang Zhigang, Zhou Rongqi, Duan Zhanting. Adsorption and Desorption Behaviour of Taurine on Macroporous Adsorption ResinsEJ].JChemTechnoBiotechnol, 2001, 76(7): 752- 756.
  • 2詹约章,余建飞.超临界机组腐蚀、结垢和积盐分析及处理对策[J].工业水处理,2012,32(6):89-92. 被引量:7
  • 3Mets:ijoki J, Huttunen-Saarivirta E, Lepist6 T. Elevated-Tem- perature Corrosion of Uncoated and Aluminized 9-12% Cr Boiler Steels Beneath KC1DepositEJ]. Fuel, 2014, 133:173 - 181.
  • 4Hansen L A, Nielsen H P, Frandsen F J, et al. Influence of Deposit Formation on Corrosion at a Straw-Fired Boiler [Jl. FuelProcessTechnol, 2000, 64(1): 189-209.
  • 5Michelsen H P, Frandsen F, Dam-Johansen K, et al. Deposi- tion and High Temperature Corrosion in a 10 MW Straw FiredBoiler[J].FuelPmcessTechnol, 1998, 54(1): 95-108.
  • 6Nielsen H P, Baxter L L, Sclippab G, et al. Deposition of Potassium Salts on Heat Transfer Surfaces in Straw-Fired Boilers: A Pilot-Scale Study [ J ]. Fuel, 2000, 79 (2) : 131 - 139.
  • 7Grahl S, Beckmann M. In-Situ Analysis of Deposit Properties in Steam Generators [J]. lnt J Therm Sci, 2013, 72:172 - 183.
  • 8魏振国.5号汽轮机通流部分积盐的原因分析及防范[J].内蒙古电力技术,1999,17(2):19-20. 被引量:4
  • 9薛晓燕,孟瑞钧,林纳新.25MW汽轮机积盐分析[J].内蒙古电力技术,2004,22(1):53-54. 被引量:2
  • 10赵玉栓,董玉.过热器积盐的成因分析与防范措施[J].科技传播,2011,3(11):34-35. 被引量:4

二级参考文献35

共引文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部