摘要 通过对两种不同方法测定废气中的二氧化硫的比较,研究发现一氧化碳气体导致定电位电解法测定二氧化硫浓度偏高,对非分散红外吸收法测定影响不大。研究结果表明:对于电化学法测定二氧化硫,废气中一氧化碳浓度越高对二氧化硫浓度的测定结果偏差越显著;当一氧化碳浓度一定时,二氧化硫浓度越低,受影响越大。 The study has compared the two sulfur dioxide concentrations obtained from the sulfur dioxide measurement by using the two different methods: the constant potential electrolysis and the non-dispersive infrared absorption method, and has found that the carbon monoxide gas causes the sulfur dioxide concentration measured by using the con- stant potential electrolysis to rise, but it has little effects on the non-dispersive infrared absorption method. The results have shown that when the constant potential electrolysis is used to measure the sulfur dioxide concentration, the higher the concentration of the carbon monoxide in the waste gas is, the more significant the deviation in the sulfur dioxide measurement is; meanwhile, when the carbon monoxide concentration is at a given level, the lower the sulfur dioxide concentration is, the more greatly the sulfur dioxide concentration is affected.
出处 《新疆环境保护》 2015年第4期24-28,共5页 Environmental Protection of Xinjiang
基金 国家科技支撑计划项目(No.2014BAC16B04) 石河子科技计划项目(NO.2015R02)
关键词 二氧化硫测定 一氧化碳 定电位电解法 非分散红外吸收法 废气 sulfur dioxide measurement carbon monoxide constant potential electrolysis non-dispersive infrared absorption method waste gas
  • 相关文献

参考文献9

二级参考文献28

  • 1汪楠,王同健,许亮,郑浩.定电位电解法测定烟道气SO_2过程中的干扰和对策[J].城市环境与城市生态,2009,22(4):41-43. 被引量:35
  • 2WANG Peng,ZHU Guo-yi.Synthesis, Fluorescence and Electrochemistry of Three New Ruthenium(Ⅱ) Complexes[J].Chemical Research in Chinese Universities,1999,15(1):81-84. 被引量:1
  • 3姜汉山,赵辉.定电位电解法测定烟道内二氧化硫准确性探讨[J].辽宁城乡环境科技,2006,26(3):35-36. 被引量:19
  • 4国家环境保护总局.HJ/T397-2007固定源废气监测技术规范[S].北京:中国环境科学出版社,2007.
  • 5[1]Chiou C Y,Chou T C.Amperometric SO2 gas sensors based on solid polymer electrolytes[J].Sensors and Actuators B,2002,B87(1):1-7.
  • 6[2]Suganuma S,watanabe M,kobayashi T,et al.SO2 gas sensor utilizing stabilized zirconia and sulfate salts with a new working mechanism[J].Solid State Ionics,1999,126(1-2):175-179.
  • 7[3]Eastman C D,Etsell T H.Thick/thin film sulfur oxide chemical sensor[J].Solid State Ionics,2000,136-137:639-645.
  • 8[4]Zhuiykov S.Development of dual sulfur oxides and oxygen solid state sensor for "in situ" measurements[J].Fuel,2000,79(10):1255-1265.
  • 9[5]Currie J F,Essalik A,Marusic J C.Micromachined thin film solid state electrochemical CO2,NO2,SO2 gas sensors[J].Sensors and Actuators B,1999,59(2-3):235-241.
  • 10[6]Tomchenko A A,Harmer G P,Marquie B T,et al.Semiconduc-ting metal oxide sensor array for the selective detection of combustion gases[J].Sensors and Actuators B,2003,93(1-3):126-134.

共引文献226

同被引文献32

引证文献5

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部