摘要
目的探讨胶体金免疫层析法检测心肌标志物在急性心肌梗死诊断中的应用价值。方法选取我院收治的60例急性心肌梗死患者,均采用胶体金免疫层析法对肌钙蛋白T(c Tn T)、肌酸激酶同工酶(CK-MB)、肌红蛋白(MYO)3种标志物进行检测。结果本组患者c Tn T、CK-MB、MYO在胸痛发作6 h内检测敏感率分别为81.7%、61.7%、96.7%,8h内检测3者敏感性分别为91.0%、70.0%、99.0%,特异性分别为100%、91.0%、79.0%,漏诊率分别为9.0%、30.0%、1.0%,误诊率分别为0/9.0%、21.0%。结论采用胶体金免疫层析法检测心肌标志物诊断心肌梗死价值显著。
Objective To investigate the application value of cardiac markers by colloidal gold assay in the diagnosis of acute myocardial infarction. Methods Selected our hospital of 60 cases of patients with acute myocardial infarction(mi),used colloidal gold immune chromatography of troponin T(c Tn T),creatine kinase isoenzyme(CK-MB),myoglobin(MYO)three markers for testing. Results CK-MB,MYO and c Tn T in the patients with chest pain in 6h were 81.7%,61.7%,96.7%,respectively,and the sensitivity of 8h were 91%,70%,99% respectively,the specificity were 100%,91%,9%,the missed diagnosis rate were 79%,30%,1% respectively,the misdiagnosis rate were 0/9.0%,21%,respectively. Conclusion The value of myocardial infarction by colloidal gold immuno chromatographic assay is significant and can be popularized.
出处
《中国卫生标准管理》
2015年第31期144-145,共2页
China Health Standard Management
关键词
胶体金免疫层析法
心肌标志物
急性心肌梗死诊断
Colloidal gold immuno chromatography assay
Myocardial markers
Acute myocardial infarction diagnosis