期刊文献+

角膜屈光手术SMILE的临床安全性、有效性及稳定性评估 被引量:10

Evaluation of the clinical safety,efficacy,and stability of small incision lenticule extraction
下载PDF
导出
摘要 小切口角膜基质透镜取出术(SMILE)是一种新型的角膜屈光手术方式,其无瓣、微创等特点在近视及散光矫正方面与既往的角膜屈光手术类型相比具有独特的优势。SMILE的安全性、有效性及可预测性经过临床大量数据研究已显示出满意的效果。但其长期稳定性尚需要进一步观察。本文针对SMILE手术技术的安全性、有效性及稳定性作一评述,以期为临床合理治疗提供参考。 Small incision lenticule extraction ( SMILE) is a novel type of corneal refractive surgery.It has unique advan-tages of minimal invasion in myopia and myopic astigmatism treatment over other corneal refractive surgeries.It has been clinically verified that the safety, efficacy and predictability of SMILE is satisfying by a series of data in clinic, whereas fur-ther researches are still needed about the long-term stability.Research progress of these points of SMILE was clarified in this article.
出处 《大连医科大学学报》 CAS 2015年第6期521-525,共5页 Journal of Dalian Medical University
基金 北京市卫生系统高层次卫生技术人才基金项目(2013-2-023)
关键词 小切口角膜基质透镜取出术 有效性 安全性 可预测性 稳定性 small incision lenticule extraction safety efficacy predictability stability
  • 相关文献

参考文献34

  • 1Shah R, Shah S, Sengupta S. Results of small incision lenticule extraction: All-in-one femtosecond laser refractive surgery[J]. J Cataract Refract Surg, 2011, 37(1): 127-137.
  • 2Sekundo W, Kunert KS, Blum M. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study[J]. Br J Ophthalmol, 2011, 95(3): 335-339.
  • 3Randleman JB, Dawson DG, Grossniklaus HE, et al. Depth-dependent cohesive tensile strength in human donor corneas: implications for refractive surgery[J]. J Refract Surg, 2008, 24(1): S85-S89.
  • 4El-Massry AA, Goweida MB, Shama Ael-S, et al. Contralateral Eye Comparison Between Femtosecond Small Incision Intrastromal Lenticule Extraction at Depths of 100 and 160 μm[J]. Cornea, 2015, 34(10): 1272-1275.
  • 5Wallau AD, Campos M. One-year outcomes of a bilateral randomised prospective clinical trial comparing PRK with mitomycin C and LASIK[J]. Br J Ophthalmol, 2009, 93(12): 1634-1638.
  • 6Kamiya K, Shimizu K, Ohmoto F. Comparison of the changes in corneal biomechanical properties after photorefractive keratectomy and laser in situ keratomileusis[J]. Cornea, 2009, 28(7): 765-769.
  • 7Dou R, Wang Y, Xu L, et al. Comparison of Corneal Biomechanical Characteristics After Surface Ablation Refractive Surgery and Novel Lamellar Refractive Surgery[J]. Cornea, 2015, 34(11): 1441-1446.
  • 8Reinstein DZ, Archer TJ, Randleman JB. Mathematical model to compare the relative tensile strength of the cornea after PRK, LASIK, and small incision lenticule extraction[J]. J Refract Surg, 2013, 29(7): 454-460.
  • 9Sinha Roy A, Dupps WJ, Roberts CJ. Comparison of biomechanical effects of small-incision lenticule extraction and laser in situ keratomileusis: finite-element analysis[J]. J Cataract Refract Surg, 2014, 40(6): 971-980.
  • 10Li M, Zhou Z, Shen Y, et al. Comparison of corneal sensation between small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK for myopia[J]. J Refract Surg, 2014, 30(2): 94-100.

二级参考文献44

  • 1Ya-Li Zhang,Lei Liu,Chang-Xia Cui,Ming Hu,Zhao-Na Li,Li-Jun Cao,Xiu-Hua Jing,Guo-Ying Mu.Comparative study of visual acuity and aberrations after intralase femtosecond LASIK:small corneal flap versus big corneal flap[J].International Journal of Ophthalmology(English edition),2013,6(5):641-645. 被引量:4
  • 2Kymionis GD,Kankariya VP,Plaka AD,et al.Femtosecond laser technology in corneal refractive surgery:a review[J].J Refract Surg,2012,28:912-920.
  • 3Kullman G,Pineda R 2nd.Alternative applications of the femtosecond laser in ophthalmology[J].Semin Ophthalmol,2010,25:256-264.
  • 4Sekundo W,Kunert KS,Blum M.Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism:results of a 6 month prospective study[J].Br J Ophthalmol,2011,95:335-339.
  • 5Shah R,Shah S,Sengupta S.Results of small incision lenticule extraction:all-in-one femtosecond laser refractive surgery[J].J Cataract Refract Surg,2011,37:127-137.
  • 6Vestergaard A,Ivarsen AR,Asp S,et al.Small-incision lenticule extraction for moderate to high myopia:predictability,safety,and patient satisfaction[J].J Cataract Refract Surg,2012,38:2003-2010.
  • 7Hjortdal JO,Vestergaard AH,Ivarsen A,et al.Predictors for the outcome of small-incision lenticule extraction for myopia[J].J Refract Surg,2012,28:865-871.
  • 8Ivarsen A,Asp S,Hjortdal J.Safety and complications of more than 1500 small-incision lenticule extraction procedures[J].Ophthalmology,2014,121:822-828.
  • 9Beer MH,Hjortdal JO,Ehlers N.Efficacy and safety of laser-assisted in situ keratomileusis for myopia[J].Ugeskr Laeger,2005,167:3688-3691.
  • 10D'Arcy FM,Kirwan C,O'Keefe M.Ten year follow up of laser in situ keratomileusis for all levels of myopia[J].Acta Ophthalmol,2012,90:e335-e336.

共引文献37

同被引文献94

  • 1Benito A, Redondo M, Artal P.Laser in situ keratomileusis disrupts the aberration compensation mechanism of the human eye.Am J Ophthalmol,2009;147(3):424-431.
  • 2Chalita MR, Chavala S, Xu M, et al.Wavefront analysis in postLASIK eyes and its correlation with visual symptoms, refraction, and topography.Ophthalmology,2004; 111(3): 447-453.
  • 3Kim A, Chuck RS.Wavefront - guided customized corneal ablation.Curr Opin Ophthalmol,2008;19(4): 314-320.
  • 4Randleman JB, Perez - Straziota CE, Hu MH, et al.Higher - order aberrations after wavefront - optimized photorefractive keratectomy and laser in situ keratomileusis.J Cataract Refract Surg,2009; 35(2):260-264.
  • 5Cheng AC.Wavefront-guided versus wavefront-optimized treatment.J Cataract Refract Surg,2008;34(8):1229-1230.
  • 6Taneri S, Oehler S, MacRae SM.Aspheric wavefront-guided versus wavefront - guided LASIK for myopic astigmatism with the Technolas 217z100 excimer laser.Graefes Arch Clin Exp Ophthalmol,2013; 251(2): 609-616.
  • 7Wan XH, Li SM, Xiong Y, et al.Ocular monochromatic aberrations in a rural chinese adult population.Optom Vis Sci2014;91(1):68-75.
  • 8Bottos KM, Leite MT, Aventura-lsidro M, et al.Corneal asphericity and spherical aberration after refractive surgery.J Cataract Refract Surg,2011;37(6):1109-1115.
  • 9Kwon Y, Bott S.Postsurgery corneal asphericity and spherical aberration due to ablation eficiency reduction and cornea1 remodeling in refractive surgeries.Eye,2009; 23(9):1845-1850.
  • 10Goyal JL, Garg A, Arora R, et al.Comparative evaluation of higherorder aberrations and corneal asphericity between wavefront-guided and aspheric LASIK for myopia.J Refract Surg,2014;30(11):777-784.

引证文献10

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部