集成多生理参数监测的终端设计 被引量:16

Design of integrated multi-physiological parameter monitoring end device
下载PDF
导出
摘要 针对目前健康监测终端设备的弊端,设计了一种便携式多生理参数监测终端。终端设备以ARM微处理器STM32F405为控制与信号处理核心,通过对多种传感器采集的信号进行实时处理和分析,获取脉率、呼吸、血氧饱和度(SPO_2)、脉搏传输时间(PTT)、心电图(ECG)以及光电容积脉搏波(PPG)信息,可实时显示生理参数和波形信息,通过触控屏完成人机交互功能,可方便实现手持式和穿戴式测量方式的自由切换。测量数据可本地存储或者通过蓝牙、ZigBee无线发送。通过实验测试,该设备测量的生理参数数据准确可靠。 Aiming at defects of health monitoring end devices at present, a portable multi-physiological parameter monitoring end device is designed. Control and signal processing functions are realized through ARM microprocessor STM32F405;information such as pulse rate, respiratory rate, surplus pulse 02, ( SPO2 ) pulse transmission time(PTT), electrocardiogram (ECG), photoplethysmography (PPG) can be obtained by real time processing and analyzing signal acquired by sensors;physiological parameters and waveforms can be displayed in real-time; man-machine interactive function can be realized through touch screen; hand-held and wearable measurement modes can be freely switched as needed. Measurement data can be saved locally or wirelessly sent through Bluetooth or Zig Bee. Experiments show that physiological parameters measured by the end device are accurate and reliable.
出处 《传感器与微系统》 CSCD 2016年第1期95-97,共3页 Transducer and Microsystem Technologies
基金 国家高技术研究发展"863"计划资助项目(2012AA040506 2013AA041201) 国家自然科学基金资助项目(61302033)
关键词 多生理参数监测 脉率 呼吸率 血氧饱和度 脉搏传输时间 心电图 光电容积脉搏波 multi-physiological parameter monitoring pulse rate respiratory rate surplus pulse 02 ( SPO2 ) pulse transmission time (PTT) electrocardiogram (ECG) photoplethysmography (PPG)
  • 相关文献

参考文献7

  • 1Mundt Carsten W, Montgomery Kevin N, Udoh Usen E, et al. Amultiparameter wearable physiologic monitoring system for spaceand terrestrial applications [ J ]. IEEE Transactions on InformationTechnology in Biomedicine,2005,9(3) :382 —391.
  • 2Klingeberg T,Schilling M. Mobile wearable device for long termmonitoring of vital signs [ J ]. Computer Methods and Programs inBiomedicine,2012,106(2) :89 -96.
  • 3Chen Xianxiang,Fang Zhen,Ren Ren,et al. Simple and efficientbaseline removal method for a smartphone based ECG detectiondevice[ J], WIT Transactions on Engineering Sciences,2013,86:987-993.
  • 4Yuan Zuo, Fang Zhen, Chen Xianxiang, et al. A novel reflectionpulse oximeter for home health care applications[C]//IntelligentSystems Design and Engineering Applications,Hunan,2014:64 -68.
  • 5Shelley K H,Jablonka D H,A Wad A A,et al. What is the bestsite for measuring the effect of ventilation on the pulse oximeterwaveform [ J ]. Anesthesia & Analgesia, 2006,103 (2 ) : 372 —377.
  • 6Gribbin Brian,Steptoe Andrew,Sleight Peter. Pulse wave velocityas a measure of blood pressure change [ J ]. Psychophysiology,1976,13(1) :86 -90.
  • 7Pan Jiapu,Tompkins Willis J. A real-time QRS detection algorith-m[ J]. IEEE Transactions on Biomedical Engineering ( BME ),1985 ,32(3) :230 -236.

同被引文献125

引证文献16

二级引证文献77

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部