摘要 目的 探讨旋入式自锁髓内钉治疗长管状骨骨折的优点及疗效。方法 采用有限切开复位旋入式自锁髓内钉治疗骨折25例,其中股骨干骨折9例,肱骨干骨折6例,胫骨干骨折10例,并随访4~24个月。结果 25例骨折均骨性愈合,愈合时间15~30周,平均21周,肢体功能恢复良好,无断针情况。结论 旋入式自锁髓内钉以长骨中轴线髓内固定,强度大、无应力遮挡和应力集中、手术操作简便、骨折端可适当加压,骨折愈合率高效果令人满意。
作者 吕志盛
出处 《中国医药指南》 2016年第2期131-131,共1页 Guide of China Medicine
  • 相关文献

参考文献8

  • 1Patterson BM,Roult ML,Benirschke SK,et al.Retrograde nailing of femoral shaft fracture[J].J Trauma,1995,38(1):38.
  • 2Gregovy P,Dicicco J,Karpik,et al.Ipsilateral Fractures of the femur and tibia:Treament with retrograde nailing and undreamed tibial nailing[J].Orthop Trauma,1969,10(5):309-316.
  • 3王亦璁.骨折治疗的微创术式[J].中华骨科杂志,2002,22(3):190-192. 被引量:207
  • 4张兴庆,冯桂菊.交锁髓内钉固定治疗胫骨骨折的体会[J].中华现代临床医学杂志,2002,(8):103.
  • 5罗先正,邱贵兴.髓内针内固定[M].北京:人民卫生出版社,2000,121~130.
  • 6王琳,康志刚,苏斌.交锁髓内钉与旋入式髓内钉治疗胫骨干骨折[J].中国中西医结合外科杂志,2011,17(5):547-547. 被引量:6
  • 7田少渠.可膨胀自锁髓内钉治疗四肢长骨骨折[J].中国实用医刊,2011,38(4):48-49. 被引量:4
  • 8渠继武.旋入式自锁髓内钉治疗胫骨中下段骨折临床疗效分析[J].中外健康文摘,2013,10(30):273-274.

二级参考文献23

  • 1Gomez-Benito MJ,Fornells P,Garcia-Aznar M.et al.Computational comparison of reamed versus unreamed intramedullary tibial nails[J].orthpes,2007,25(2):191.
  • 2Krettek C, Schandelmaier P, Tscherne H.Nonreamed interlocking nailing of closed tibial fractures with severe soft tissue injury.Clin Orthop, 1995, (315): 34-47.
  • 3Gregory P, Sanders R. The treatment of closed, unstable tibial shaft fractures with unreamed interlocking nails. Clin Orthop,1995, (315): 48 -55.
  • 4Blachut PA, Meek RN, O'Brien PJ. External fixation and delayed intramedullary nailing of open fractures of the tibial shaft: a sequential protocol. J Bone Joint Surg(Am), 1990,72:729 -735.
  • 5Mayr E, Braun W, Ruter A. Can unreamed tibial nailing replace external fixators in management of open tibial fractures?Chirurg, 1994, 65: 983-987.
  • 6Palmer RH. Biological osteosynthesis. Vet Clin North Am Small Anim Pract, 1999, 29:1171 - 1185.
  • 7Weller S. Hontzsch D. Frigg R.Epiperiostal, percutaneous plate osteosvnthesis: a new minimally invasive technique with reference to "biological osteosynthesis".Unfallchirurg. 1998.101: 115-121.
  • 8Farouk O, Krettek C. Miclau T. et al.Minimally invasive plate osteosvnthesis: dose percutaneous plating disrupt femoral blood supply less than the traditional technique? J OrthopTruama. 1999. 13:401-406.
  • 9Ruedi TP, Sommer C, Leutenegger A. New techniques in indirect reduction of long bone fractures. ClinOrthop, 1998, (347): 27-34.
  • 10Gautier E, Ganz R The biological plate osteosvnthesis. Zentralbl Chin 1994, 119:564 - 572.

共引文献216

同被引文献7

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部