摘要 为了使用低成本、无创伤且易操作的方法评估人体心血管的健康状况,设计一个基于ARM11(S3C6410)的无创心血管健康评估系统,该系统由无创心血管参数检测探头、嵌入式人机交互平台和内嵌的健康评估模型3个部分组成;基于能量代谢守恒法、指端容积脉搏波检测等研制出无创检测探头,用于测量血压、血流速度和血糖等人体参数,采用蓝牙4.0设备将数据传输至嵌入式人机交互平台,数据经改进后的国人缺血性心血管病(ICVD)10年发病危险评估模型得出健康评估结果;实验结果表明该方法所得评估结果和微创真值经原始ICVD评估模型所得评估结果的Pearson相关系数为0.91(Spearman相关系数为0.891),说明该方法是可行的。 In order to assess cardiovascular health by low-cost, non-invasive and easy-to-handle method, the non-invasive cardiovascular health assessment system based on ARM11(S3C6410) which is composed of non-invasive cardiovascular parameters measurement sensor, embedded GUI platform and embedded health assessment model was designed. According to the method of conservation of energy metabolism and the detection of fingertip volume pulse waves, the sensor for blood pressure, blood flow velocities and non-invasive blood glucose measurement was designed. The embedded GUI platform will display the health assessment results when the body parameters which were measured by the sensor and were transferred to the embedded GUI platform by Bluetooth 4.0 device were operated on the improved evaluation model of the ten years risk of ischemic cardiovascular diseases (ICVD) in Chinese. The experimental results indicated the Pearson correlation coefficient was 0.91(Spearman correlation coefficient was 0.891) between the test values and the true values of the health assessment, which indicated this method is feasible.
出处 《计算机测量与控制》 2016年第1期300-302,307,共4页 Computer Measurement &Control
基金 广西自动检测技术与仪器重点实验室主任基金项目(YQ14116) 国家自然科学基金(61271119) 国家科技支撑计划(2013BAI03B01) 广西高等学校科学研究项目(KY2015YB096) 桂林电子科技大学研究生教育创新计划资助项目(GDYCSZ201479)
关键词 心血管健康评估 人机交互平台 无创检测 non-- invasive measurement GUI platform cardiovascular health assessment
  • 相关文献

参考文献10

二级参考文献25

  • 1向海燕,俞梦孙.用脉搏波传导时间实现血压连续测量[J].医疗卫生装备,2006,27(2):19-21. 被引量:31
  • 2张红叶,杨军,周北凡,武阳丰,李莹,陶寿淇.我国十组人群脑卒中危险因素的前瞻性研究[J].中国慢性病预防与控制,1996,4(4):150-152. 被引量:91
  • 3Harutyun M, Emma D, Seungwan K, et al. Non-Invasive in vitro Sensing of D-Glucose in Pig Blood [ J ]. Medical Engineering and Physics ,2012,34 ( 3 ) :299-304.
  • 4Seungwan K, Harutyun M, Jongchel K, et al. Noninvasive in vitro Measurement of Pig-Blood D-Glucose by Using a Microwave Cavity Sensor [ J ]. Diabetes Research and Clinical Practice, 2012,96 ( 3 ) : 379-384.
  • 5Christopher M, David H, Patricia C. Towards Blood Free Measurement of Glucose and Potassium in Humans Using Reverse Iontophoresis [ J ]. Sensors and Actuators B : Chemical, 2012,166 - 167 ( 5 ) :593-600.
  • 6Cai Y Y, Cao D, He X H, et al. Continuous Glucose Monitoring System Based on Smart Phone [ J]. Procedia Engineering, 2012, 29 : 3894-3898.
  • 7Sandeep K V. Non-Invasive Glucose Monitoring Technology in Diabetes Management: A Review [ J ]. Analytica Chimica Acta, 2012,750(10) :16-27.
  • 8Hisako H, Mihara M, Lida T, et al. Blood Glucose Measurement for Flap Monitoring to Salvage Flaps from Venous Thrombosis [ J ]. Journal of Plastic, Reconstructive and Aesthetic Surgery,2012,65 (5) :616-619.
  • 9Dongmin G, David Z, Lei Z, et al. Non-Invasive Blood Glucose Monitoring for Diabetics by Means of Breath Signal Analysis [ J ]. Sensors and Actuators B :Chemical,2012,173 : 106-113.
  • 10Enric M M. Non-Invasive Estimate of Blood Glucose and Blood Pressure from a Photoplethysmograph by Means of Machine Learning Techniques[ J]. Artificial Intelligence in Medicine,2011, 53(2) :127-138.

共引文献1082

同被引文献62

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部