摘要 为了提取表征油纸绝缘老化状态的新特征量,将时域介电响应技术应用于变压器油纸绝缘老化状态的无损评估,并在深入研究了不同老化状态对油纸绝缘时域介电特性影响的基础上,首先分析了油纸绝缘样品等效扩展Debye模型参数随热老化状态变化的规律,然后提取了四组可用于表征油纸绝缘老化状态的特征参量,并建立了特征参量与绝缘老化状态之间的量化关系。研究表明:扩展Debye模型等效电路参数对油纸绝缘老化状态的反映比较敏感,最小和最大时间常数分支的R、C参数均可以反映绝缘纸的老化状态;最大时间常数分支的参数Rmax和最小时间常数分支的参数Cmin与绝缘纸聚合度存在线性拟合关系,而最小时间常数分支的参数Rmin和最大时间常数分支的参数Cmax与绝缘纸聚合度具有指数函数关系;文中提取的特征量可应用于油纸绝缘的老化状态评估。 In order to extract new characteristic parameters to realize the non-destructive diagnosis of aging state of transformer oil-paper insulation by time domain dielectric response technology, the influence of the aging degree on time-domain dielectric property of oil-paper insulation is investigated. The extended Debye model for oil-paper insulation is further introduced to analyze the influences of thermal degree aging on its parameters. Then four groups of characteristic parameters are extracted to reflect the aging state of the oil-paper insulation. The quantitative relationship between the characteristic parameters and the aging state thus has been established. The test results show that the parameters of the extended Debye model are quite sensitive to the aging state. The parameters of the smallest and the largest time constant branches are both able to characterize the aging state of the insulating pressboards. An obvious exponential rule can be observed between parameters Rmin, Cmax andthe degree of polymerization(DP) of the insulation paper, while the parameters R Cmin exhibit an evident linear rules with DP. The extracted characteristic parameters in this paper can be used for the aging assessment of the oil-paper insulation.
出处 《电工技术学报》 EI CSCD 北大核心 2016年第4期211-217,共7页 Transactions of China Electrotechnical Society
基金 国家自然科学基金资助项目(51277187)
关键词 油纸绝缘 热老化 极化去极化电流 扩展Debye模型 特征参量 老化评估 Oil-paper insulation, thermal aging, polarization and depolarization current, extendedDebye model, characteristic parameters, aging assessment
  • 相关文献

参考文献19

  • 1廖瑞金,梁帅伟,杨丽君,王红梅,孙才新,孙会刚.天然酯-普通纸(或热稳定纸)绝缘热老化特性[J].电工技术学报,2009,24(12):12-17. 被引量:15
  • 2Pahlavan pour B, Linaker R, Povazan E. Extension of life span of power transformer on-site improvement of insulating materials[C]//IEE Colloquium on Assess- ment of Degradation within Transformer Insulation Systems, London, UK, 1991: 6/1-6/4.
  • 3Emsley A M, Stevens cators of degradation G C. Review of chemical indi- of cellulosic electrical paper insulation in oil-filled transformers[J], lEE Proceedings of Science, Measurement and Technology, 1994, 141(5): 324-334.
  • 4Shroff D H, Stannett A W. A review of paper aging in power transformers[J]. IEE Proceedings of Generation, Transmission and Distribution, 1985, 132(6): 312- 319.
  • 5Pahlavanpour P, Eklund, Martins M A. Insulating paper ageing and furfural formation[C]//Proceedings of 2003 Electrical Conference Insulation and Electrical Manufacturing & Amp; Coil Winding Technology Conference, Indianapolis, United States, 2003: 283- 288.
  • 6Saha T K. Review of modern diagnostic for assessing insulation condition in formers[J] Electrical IEEE Transactions on Diel techniques aged trans- ectrics and Insulation, 2003, 10(5): 903-917.
  • 7Zaengl W S. Application of dielectric spectroscopy in time and frequency domain for HV power equip- ment[J]. IEEE Electrical Insulation Magazine, 2003, 19(6): 9-22.
  • 8Blennow J, Ekanayake C, Walczak K, et al. Field experiment with measurement of dielectric response in frequency domain for power transformer diagno- stics[J]. IEEE Transactions on Dielectric and Electrical Insulation, 2006, 21 (2): 681-688.
  • 9Saha T K, Purkait P. Investigation of polarization and de polarization current measurements for the assessment of oil-paper insulation of aged transformers[J]. IEEE Transactions on Dielectric and Electrical Insulation, 2004, 11(1): 144-154.
  • 10Yang Lijun, Gubanski S M, Serdyuk Y V, et al. Dielectric properties of transformer oils for HVDC applications[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2012, 19(6): 1926-1933.

二级参考文献35

  • 1岂小梅.变压器绕组变形的综合判断及经验总结[J].电网技术,2006,30(S1):220-222. 被引量:29
  • 2王永强,律方成,李和明.基于粗糙集理论和贝叶斯网络的电力变压器故障诊断方法[J].中国电机工程学报,2006,26(8):137-141. 被引量:99
  • 3廖瑞金,杨丽君,孙才新,李剑.基于局部放电主成分因子向量的油纸绝缘老化状态统计分析[J].中国电机工程学报,2006,26(14):114-119. 被引量:79
  • 4李晓虎,李剑,杜林,杨丽君,孙才新.一种转基因菜籽绝缘油的电气性能[J].中国电机工程学报,2006,26(15):95-99. 被引量:42
  • 5Saha J K, Darreniza M, Hill D J T. Investigating the effects of oxidation and thermal degradation on electrical and chemical properties of power transformers insulation[J]. IEEE Transactions on Power Delivery, 1999, 14(4): 1359-1367.
  • 6Boss P, Oommen T V transformers based on New insulating fluids for biodegradable high oleic vegetable oil and ester fluid[C]. IEE Colloquium on Insulating Liquids, London, 1999.
  • 7Oommen T V. Vegetable oils for liquid filled transformers[J]. IEEE Electrical Insulation Magazine, 2002, 18(1): 6-11.
  • 8Badent R, Hemmer M, Schwab A J. Inhibited rape-seed oil as substitute for mineral oils[C] Conference on Electrical Insulation and Dielectric Phenomena, Quintana Roo, Mexico, 2002.
  • 9Hemmer M, Badent R, Leibfriend T. Investigation of the suitability of commercially available bio-oils as insulating liquid[C]. Annual Report Conference on Electrical Insulation and Dielectric Phenomena, Virginia, 2003.
  • 10Hemmer M, BadenT R, Schwab A J. Electrical properties of rape seed oil[C]. Annual Report Conference on Electrical Insulation and Dielectric Phenomena, Virginia, 2003.

共引文献110

同被引文献367

引证文献36

二级引证文献236

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部