摘要 采用奇偶模分析法推导得到两级级联功分网络在给定工作带宽时的最佳归一化功分臂特征阻抗值和隔离电阻值,并比工作带宽为80%的二级功分器为例进行了电路设计和实验测试。实验结果显示,在3~7 GHz频率范围内,功分器输入、输出回波损耗分别大于18.8 d B和21.1 d B,隔离度大于30 d B。该方法对任意频段的级联功分网络均可适用。 In this paper,normalized arm impedance and isolation resistor of the two cascaded power divider network is calculated by using even and odd mode analysis while the operating bandwidth is given. Further,the operating bandwidth of 80% of the power divider is designed and measured. Experimental results show that in the frequency range 3 ~ 7 GHz,the input and output return loss are greater than 18. 8 d B and 21. 1 d B,isolation greater than 30 d B. The method for any frequency band power divider network can be applied.
作者 陆东一
出处 《常州信息职业技术学院学报》 2016年第1期29-31,共3页 Journal of Changzhou College of Information Technology
关键词 奇偶模 宽带 功分器 even and odd modes broadband power divider
  • 相关文献

参考文献3

  • 1L. Young. [ Tables for cascaded homogeneous quarter- wave transformers ]. IRE Trans. Microw. Theory Tech, Apr. 1959:vol. MTT-7, no. 3, pp. 233-237.
  • 2Moore J. [ Ling H., "Characterization of a 90° microstrip bend with arbitrary miter via the tkne-domain t-mite differ- ence method]. IEEE Trans. Microw. Theory Techn. ,April 1990:Vol. 38, Issue 4, pp. 405-410.
  • 3Y. Xu and R. Bosisio. [ Design of multi-way power divider by using stepped-impedance transformers ]. IEEE Trans. Microw. Theory Techn., Sep. 2012: vol. 60, no. 9, pp. 2781-2790.