5HAUEISEN H, H EIDEM ANN D. Hemisection for treatment of an advanced endodontic-periodontal lesion: a case report [J]. Int Endod J, 2002, 35(6): 557-572.
6WANG J, LIU QM. Clinical application of hemisection in the treatment of tooth with disease [J]. Shanxi Med J, 2008, 37(11): 1042-1043. Chinese.
7RAPOPORT R H, DEEP P. Traumatic hemisection and restora- tion of a maxillary first premolar: a case report [J]. Gen Dent, 2003, 51(4): 340-342.
8ZHAO YM, CHEN JH, WANG ZY, et al. Prosthodontics[M]. 6th ed. Beijing: People's Medical Publishing House, 2008: 34.
9HIRANO K, HIRANO S, HAYAKAWA I. The role of oral sen- sofimotor function in masticatory ability[J]. J Oral Rehabil, 2004, 31(3): 199-205.
10HORI K, ONO T, NOKUBI T. Coordination of tongue pressure and jaw movement in mastication [J]. J Dent Res, 2006, 85(2): 187-191.
2Naveen YG, Patel JR,Parikh P, et al.Alternatives for restoration of a hemisected mandibular molar.BMJ Case Rep,2014;30(7):75.
3Pjetursson BE,Tan K,Lang NP, et al.A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years.Clin Oral [mplants Res. 2004;15(6):625-642.
4Shigemitsu R,Yoda N,Ogawa T, et al. Biological-data- based finite-element stress analysis of mandibular bone with implant-supported overdenture.Comput Biol Med,2014; 54(6):44-52.
5Desai SR,Karthikeyan I,Singh R.Evaluation of micromovements and stresses around single wide-diameter and double implants for replacing mandibular molar: a three-dimensional FEA.ISRN Dent,2012;7(4):1-10.
6Toniollo MB,Macedo AP, Pupim D,et al. Three-Dimensional Finite Element Analysis Surface Stress Distribution on Regular and Short Morse Taper Implants Generated by Splinted and Nonsplinted Prostheses in the Rehabilitation of Various Bony Ridges. J Craniofac Surg,2016;27(3):e276-280.
7Hasan I,RSger B,Heinemann F, et al.lnfluence of abutment design on the success of immediately loaded dental implants: Experimental and numerical studies. Med Eng Phys. 2012;34(7):817-825.
8Chang HS,Chen YC,Hsieh YD,et al.Stress distribution of two commercial dental implant systems: A three-dimensional finite element analysis.J Dent Sci. 2013: 8(2):261-271.
9Marcin P, Borak L,Val&,ek J,et al.Finite element analysis of dental implant loading on atrophic and non-atrophic cancellous and cortical mandibular bone - a feasibility study.J Biomech,2014;47(16):3830-3836.
10Bouazza-Juanes K,Martinez-Gonzllez A,Peir0 G, et al. Effect of platform switching on the peri-implant bone: A finite element study.J Clin Exp Dent 2015;7(4):e483-488.