期刊文献+

基于历史数据的HJ-1B/IRS热红外通道定标与分析 被引量:2

Calibration and analysis of HJ-1B/IRS thermal infrared channel based on the historical data
原文传递
导出
摘要 为获取2013年HJ-1B/IRS热红外通道(B08)绝对辐射定标系数,以TERRA/MODIS为参考传感器,以青海湖为研究区域,采用双通道差分模型进行交叉定标。对比分析不同观测角度、成像时差对定标精度的影响,结果表明,参考传感器观测角度30°以内、成像时差1 h左右交叉定标条件最佳,且回归拟合的定标系数精度最高。通过采用2013年10月26日宁德附近海域星地同步实验数据进行精度验证,结果表明,此定标系数得到的表观辐亮度误差在0.02 Wm-2μm-1sr-1以内,表观亮温误差在0.15℃以内。同时,通过与历年辐射定标系数(2008-2012年)进行对比,所得定标系数精度分别提高98.50%、98.24%、90.21%、20.87%和98.31%。总之,此文定标系数精度较高、结果可靠,可应用于IRS B08通道。 To obtain the absolute radiation calibration coefficient of IRS B08 in 2013,TERRA/MODIS was used as the reference sensor, Qinghai lake was taken as the research object, twin-channel difference model was applied to cross-calibration. By comparing the influence of different observation angles and different of imaging receiving time on calibration precision, it can be concluded that the best cross-calibration condition is the observation angle within 30° and the difference of imaging receiving time about 1 hour. Under this condition,calibration accuracy of regression fitting is the highest. According to the precision verification using satellite-ground synchronous experiment data around Ningde area on 26, October, 2013, result shows that error of apparent radiance and brightness temperature is within 0.02 Wm-2μm-1sr-1and 0.15 ℃ respectively. Besides,compared with the historical calibration coefficients from 2008 to 2010, the new calibration coefficients of 2013 increased by 98.50%, 98.24%, 90.21%, 20.87% and 98.31% respectively. Overall, the obtained calibration coefficient has a high accuracy, that can be used to the IRS B08.
出处 《红外与激光工程》 EI CSCD 北大核心 2016年第3期45-49,共5页 Infrared and Laser Engineering
基金 国家自然科学基金(41301388)
关键词 定标 历史数据 MODIS IRS calibration historical data MODIS IRS
  • 相关文献

参考文献8

二级参考文献37

  • 1唐嘉,高昕.靶场红外辐射特性测量系统标定方法研究[J].红外与激光工程,2006,35(z1):266-270. 被引量:22
  • 2CHEN GuangMing,GAO Xu,ZHANG ShaoZhi,CHEN Qi,TANG LiMing & LAN YuQi Institute of Refrigeration and Cryogenics,Zhejiang University,Hangzhou 310027,China.Development of an automatic calibration device for high-accuracy low temperature thermometers[J].Science China(Technological Sciences),2010,53(9):2404-2407. 被引量:6
  • 3李宪圣,任建伟,张立国,万志,朱启海,赵贵军.大口径红外光电系统现场辐射定标装置的研制[J].光电子.激光,2006,17(2):175-178. 被引量:30
  • 4DINGUIRARD M,SLATER P N. Calibration of space-multispectral imaging sensors:a review [J].Remote Sensing of Environment, 1999, 65(3): 194-205.
  • 5张勇.遥感传感器热红外数据辐射定标研究.北京:中国科学院遥感应用研究所,2006:33~34.
  • 6WAN Zheng-ming, MODIS land-surface temperature algorithm theoretlcal basis document (LSTATBD) [EB/OL]. http:// modis.gsfc.nasa.gov/data/atbd -mod11. pdf,2004-05-19.
  • 7GUENTHER B, GODDEN G D, XIONG Xiao-xiong, et al. Prelaunch algorithm and data format for the level 1 calibration products for the EOS-AMI moderate resolution imaging spectroradiometer (MODIS) [J]. IEEE Transactions on Genseienee and Remote Sensing, 1998, 36(4): 1142-1265.
  • 8MORISETTE J, JUSTICS C, PRIVETTE J. MODIS land team validation update for terra and aqua [EB/OL]. http://eospso. gsfc.nasa.gov/ftp -ocs/MODLAND -valupdate -decoo.pdf , 2004- 05-19.
  • 9WAN Zheng-ming, ZHANG Yu -lin, LI Zhao-liang, et al. Preliminary estimate of calibration of the moderate resolution imaging spectroradiometer thermal infrared data using Lake Titicaca [J]. Remote Sensing of Environment, 2002, 80: 497- 515.
  • 10Merchanr C J, Simpson J J, Harris A R. A cross-calibrationof GMS-5 thermal channels against ATSR-2 [J]. RemoteSensing of Environment, 2003, 84(2): 268-282.

共引文献43

同被引文献9

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部