期刊文献+

不同制作和粘接方法对铸造金属桩核固位性影响的研究 被引量:4

Effects of Different Fabrication Techniques and Cementation Methods on the Rentention of Cast Metal Post and Core
下载PDF
导出
摘要 目的:探索铸造金属桩核制作方法、粘接方法和粘接剂种类对其固位的影响。方法:选择80颗完整的新鲜无龋坏下颌单根管双尖牙,在釉牙骨质界上2mm处去除临床牙冠,行根管治疗,根管预备和铸造桩核制作及粘接。根据制作方法将80个样本分为两大组(直接法和间接法),每组40个。每组又根据粘接方法(使用螺旋输送器和未使用)和粘接剂(玻璃离子水门汀和磷酸锌水门汀)不同下分4小组,每组10个样本。将样本置于23℃室温生理盐水中存放24h后放置于万能力学测试机上,以0.5mm/min的速度进行拉力试验直到失败,从而得出固位力大小。结果:本实验中影响固位力的最明显因素为粘接方法,使用了螺旋输送器组的固位力明显高于未使用螺旋输送器组(P<0.05);不同制作方法对固位力无明显影响(P>0.05),使用磷酸锌粘接剂组固位力高于使用玻璃离子粘接剂组。然而制作方法,粘接方法和粘接剂种类间是有密切的交互作用的(P<0.05)。结论:制作方法并不影响铸造桩核的固位力,磷酸锌粘接剂性能优于玻璃离子粘接剂,粘接方法对固位力有显著的影响,建议在粘接过程中使用螺旋输送器。 Objective:To investigate the effect of fabrication technique,cement type,and cementation procedure on rentention of cast metal post and core.Methods:Eighty intact single-rooted mandibular human premolars were selected.The clinical crown was removed at 2mm above the cementoenamel junction level.Each root was prepared to receive a cast metal post and core of 10 mm in length and 1.5mm in diameter.Eighty specimens were divided into two groups according to fabrication technique(direct=40and indirect=40).Each group was further subdivided into four groups according to the cementation type(zinc phosphate and glass ionomer),and cementation procedure(with and without lentulo spiral).All specimens were stored in physiological saline bath at 23℃ for 24 hours.Then the dowels were subjected to a constantly increasing tensile force in a universal Instron testing machine at crosshead speed of 0.5mm/min until failure.Results:Cementation with lentulo spiral showed greater retentive force than that without lentulo spiral(P〈0.05).Fabrication technique showed no significant effect on retentive force(P〉0.05).The group cemented with zinc phosphate produced greater retentive force than that of the glass ionomer group.However,there was a close interaction among fabrication technique,cementation procedure and cement type(P〈0.05).Conclusion:Fabrication technique does not affect the retentive force of cast metal post and core.Zinc phosphate cement was better than glass ionomer cement.The cementation procedure had a significant effect on retention.Thus,it is recommended that the lentulo spiral should be used in the cementation procedure.
作者 陈济芬 丁宏
出处 《口腔医学研究》 CAS CSCD 北大核心 2016年第4期408-411,共4页 Journal of Oral Science Research
关键词 桩核 固位性 直接法 间接法 Cast metal post and core Retention Direct technique Indirect technique
  • 相关文献

参考文献12

  • 1张振庭,李群,罗晨晨,廖方刚,刘耀乙.不同脱模时间对石膏模型抗折强度的影响[J].中华口腔医学杂志,2001,36(3):183-185. 被引量:12
  • 2Grundy JR, Glyn Jones JC. Crowning pulpless teeth. Part 1 [J]. Br Dent J, 1981, 150(1) : 307- 312.
  • 3Koutayas SO, Kern M. All ceramic posts and cores: the state of the art [J]. Quintessence Int, 1999, 30(6) : 383-392.
  • 4Cohen BL, Musikant BL, Deutsch AS. Comparison of reten tire properties of four post systems [J]. J Prosthet Dent 1992, 68(2): 264-268.
  • 5林少萍.应用自凝塑料制作前牙桩核的体会[J].广东医学院学报,2007,25(1):49-50. 被引量:4
  • 6刘利苹,牟月照.制取铸造桩核蜡型的体会[J].口腔颌面修复学杂志,2004,5(1):29-29. 被引量:9
  • 7Assif D, Bitenski A, Pilo R, et al. Effect of post design on resistance to fracture of endodontically treated teeth with complete crowns [J]. J Prosthet Dent, 1993, 69(1): 36- 40.
  • 8Fakiha Z, AI-Aujan A, AI-Shamrani S. Retention of cast post cemented with zinc phosphate cement using different ee-menting techniques [J]. J Prosthodont,2001,10(1) : 37-41.
  • 9Stockton LW. Factors affecting retention of post systems: aliterature review [J]. J Prosthet Dent, 1999,81(4) : 380- 385.
  • 10Soares JA, Brito-Jflnior M, Fonseca DR, et al. Influence of luting agents on time required for cast post removal by ultra- sound: an in vitro study [J]. J Appl Oral Sci, 2009, 17(3) : 145-149.

二级参考文献26

  • 1张晔,闫勇.残冠残根直接法快速制作自凝桩核的体会[J].山西医药杂志,2005,34(12):1067-1068. 被引量:1
  • 2马轩祥.残冠残根保存修复的概况与进展[J].中华口腔医学杂志,2006,41(6):333-335. 被引量:84
  • 3徐君伍.口腔修复学:4版[M].北京:北京人民卫生出版社,1999.74~75.
  • 4Morgano SM, Brackett SE. Foundation restorations in fixed prosthodontics:current knowledge and future needs [J].J Prosthet Dent,1999,82(6):643-657.
  • 5Nergiz I, Schmagc P, Platzer U, et al. Effect of different surface textures on rentitive strength of tapered posts [J].J Prosthet Dent, 1997,78(5):451-457.
  • 6Tjan AH, Greive Jh. Effects of various cementation methods on the retention of prefabricated posts [J].J Prosthet Dent,1987,58(3): 309-313.
  • 7Dykema RW, Goodacre CJ, Philips RW, et ah Johnston's modern practice in fixed prosthodontics[M].4th.Ed.Philadelphia:Saunders, 1986:364-378.
  • 8Baum L, Phillips R, Lund M. Textbook of operative dentistry,[M]. 3rd Ed.Philadelphia: Saunders, 1995:593-616.
  • 9Abou-RassM, DonovanTE. The restoration of endodontically treated teeth[J].J Calif Dent Assoc, 1993,21 (! 2):61-67.
  • 10American National Standards Institute/American Dental Association. Specification No.96(IS0 9917)for Dental Water-Based Cements[P]. Chicago:ANSI/ADA, 1994.

共引文献27

同被引文献32

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部