期刊文献+

无创血流动力学监测临床应用的研究进展 被引量:12

Research Progress of Non-invasive Hemodynamic Monitoring in Clinical Application
原文传递
导出
摘要 随着重症医学的发展,血流动力学监测也受到越来越多的关注。准确判断患者血流动力学变化能指导临床医生做出正确的治疗措施。在重症患者中,患者的前负荷,后负荷及心肌收缩力均发生巨大改变且三者相互影响。在这种情况下,准确判断患者血流动力学变化是临床工作中面临的重大挑战。目前临床上,很多血流动力学监测设备正在使用,帮助临床医生做出准确判断。近十年来,血流动力学监测从有创向微创甚至无创的方向发展,由短时监测向长时连续监测的方向发展。无创血流动力学监测设备因其操作简单及无创伤性在临床使用越来越广泛。本文主要回顾分析临床中常用几种无创血流动力学监测仪,介绍它们的作用原理,及各自的优缺点。 : With the development of critical care medicine, hemodynamic monitoring has gained more and more attention. Accurate judgement of hemodynamic could help doctors make correct treatment measures. In critically ill patients, all of preload, afterload and contractility undergo great changes and interact with each other. In this situation, it is a great challenge for clinician to estimate hemodynamics change accurately. Up to now, various devices have been used to help doctors monitor hemodynamic. In the past 10 years, hemodynamic monitoring techniques have evolved from intermittent toward continuous measurements and from an invasive towards a less invasive even non-invasive approach. Non-invasive hemodynamic devices are more and more widely used in clinical use due to easy-operating and noninvasion. A variety of non-invasive hemodynamic monitoring devices were introduced in this article, with functional mechanism clarified and advantages as well as disadvantages discussed.
出处 《现代生物医学进展》 CAS 2016年第14期2789-2792,共4页 Progress in Modern Biomedicine
基金 国家自然科学基金项目面上项目(31171093)
关键词 血流动力学监测 无创 临床应用 Hemodynamic monitoring Non-invasive Clinical application
  • 相关文献

参考文献29

  • 1Jelle B, Michael M, Britta H, et al. Hemodynamic monitoring: To calibrate or not to calibrate? Part 1 - Non-calibrated techniques [J]. Anaesthesiology Intensive Therapy, 2015, 47(5): 487-500.
  • 2Shah MR, Hasselblad V, Stevenson LW, et al. Impact of the pulmonary artery catheter in critically ill patients: Meta-analysis of randomized clinical trials[J]. JAMA, 2005, 294(13): 1664-1670.
  • 3Jelle B, Michael M, Britta H, et al. Hemodynamic monitoring: To calibrate or not to calibrate? Part 2 - Non-calibrated techniques [J]. Anaesthesiology Intensive Therapy, 2015, 47(5): 501-516.
  • 4Langwieser N, Prechtl L, Meidert AS, et al. Radial artery applanation tono-metry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit [J]. Clin Res Cardiol, 2015, 104(6): 518-524.
  • 5Meidert AS, Huber W, MO ller JN. Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure[J]. Br J Anaesth, 2014, 112(3): 521-528.
  • 6Meidert AS, Huber W, Hapfelmeier A. Evaluation of the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements in patients with multiple organ dysfunction syndrome [J]. J Crit Care. 2013.28(6): 908-912.
  • 7Saugel B, Meidert AS, Langwieser N. An autocalibrating algorithm for non-invasive cardiac output determination based on the analysis of an arterial pressure waveform recorded with radial artery applanation tonometry: a proof of concept pilot analysis[J]. J Clin Monit Comput, 2014, 28(4): 357-362.
  • 8Wagner JY, Sarwari H, Schon G. Radial artery applanation tonometry for continuous noninvasive cardiac output measurement: a compa-rison with intermittent pulmonary artery thermodilution in patients atler cardiothoracic surgery [J]. Crit Care Med, 2015, 43(7):1423-1428.
  • 9Broch O, Rermer J, Gruenewald M, et al. A comparison of the Nexfin and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery[J]. Surgery Anaesthesia, 2012, 67(4): 377-383.
  • 10Ameloot K, Palmers P J, Malbrain ML. The accuracy of noninvasive cardiac output and pressure measurements with finger cuff: a concise review[J]. Curr Opin Crit Care, 2015, 21(3): 232-239.

同被引文献97

引证文献12

二级引证文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部