摘要 目的:采用双通道视觉质量分析系统评估圆锥角膜患者角膜交联手术前后的客观视觉质量。方法:收集2015-01/07患有进展期圆锥角膜而进行紫外光-核黄素角膜交联手术的患者病例资料。利用双通道系统比较手术前和手术后6mo患者的客观散射指数(OSI)、对比度视力(VA)、调制传递函数截止频率(MTF cut off)和斯特列尔比(SR)。结果:共收录患者13例16眼。术后6mo裸眼视力、最佳矫治视力、屈光度、Sim-k平均值与术前相比差异无统计学意义(P>0.05);眼前节分析仪非侵袭平均泪膜破裂时间(NI Avg-BUT)比术前相比有明显下降,差异有统计学意义(P<0.05)。双通道视觉质量分析系统术后6mo时的MTF cut off、Strehl Ratio、OSI与术前相比差异无统计学意义(P>0.05);泪膜分析平均OSI(tear film analysis mean OSI)比术前明显升高,差异有统计学意义(P<0.05)。结论:角膜交联手术没有使患者的术后视觉质量受到影响,但对术后6mo的泪膜稳定性有轻度影响,长期结果有待进一步观察。 AIM : To evaluate the objective visual quality of patients who underwent corneal cross-linking for the keratoconus using double-pass analysis system. METHODS: Advanced keratoconus patients who underwent UV-riboflavin corneal cross-linking from January to July 2015 were included. The outcom es of their objective scattering index( OSI),predicted visual acuity( VA), the cut-off frequency of modulation transfer function( M TF cut-off), the Strehl ratio( SR) were com pared before and 6m o after corneal cross-linking. RESULTS: A total of 13 patients( 16 eyes) were included. There was no statistically significant difference between pre-and 6mo postoperative data in uncorrected visual acuity,best corrected visual acuity,refractions and m ean value of Sim-k( P 0. 05). Non-invasive average tear film break up time( NIAvg-BUT) detected by the Sirius system decreased after corneal cross-linking( P 0. 05). Using double-pass analysis system, no statistically significant change was found in M TF cut off,Strehl Ratio,OSI before and after treatm ent( P 0. 05).Tear Film Analysis M ean OSI increased at 6m opostoperatively( P0. 05). CONCLUSION: The subjective visual quality isn't effected by corneal cross-linking. The tear stabilities of patients are influenced by these operations at 6m o postoperatively. M ore observations on long-term effect are needed to be taken in the future.
出处 《国际眼科杂志》 CAS 2016年第6期1196-1198,共3页 International Eye Science
基金 河北省邢台市科技计划项目(No.2015ZZ050 No.2012ZC058)~~
关键词 双通道分析系统 圆锥角膜 交联 客观视觉质量 double-pass analysis system keratoconus cross-linking subjective visual quality
  • 相关文献

参考文献18

  • 1Zhang X, Tao XC, Zhang J, et al. A review of collagen cross-linking in cornea and sclera. J Ophthalmol 2015; 2015:289467.
  • 2Vinciguerra R, Romano MR, Camesasca FI, et al. Corneal cross-linking as a treatment for keratoconus: four-year morphologic and clinical outcomes with respect to patient age. Ophthalmology 2013; 120(5):908-916.
  • 3Xu CC, Xue T, Wang QM, et al. Repeatability and reproducibility of a double-pass optical quality analysis device. PloS One 2015; 10(2):e0117587.
  • 4乔利亚,蔡啸谷,万修华,管征,熊瑛,林仲,张烨,谭家璿,王宁利.应用双通道客观视觉质量分析系统与光线追踪波阵面像差系统分析正常人眼调制传递函数[J].中华眼科杂志,2015,51(1):20-25. 被引量:18
  • 5Wang M, Zhang F, Zhao X, et al. Riboflavin Concentration Analysis in Rabbit Corneas Before and After Corneal Collagen Cross-Linking Using Confocal Laser Scanning Microscopy. Asia Pac J Ophthalmol(Phila) 2014; 3(6):388-394.
  • 6Mastropasqua L, Lanzini M, Curcio C, et al. Structural modifications and tissue response after standard epi-off and iontophoretic corneal crosslinking with different irradiation procedures. Invest Ophthalmol Vis Sci 2014; 55(4):2526-2533.
  • 7Mastropasqua L,Lanzini M,Curcio C,et al. Morphological modification of the cornea after standard and transepithelial corneal cross-linking as imaged by anterior segment optical coherence tomography and laser scanning in vivo confocal microscopy. Cornea 2013; 32(6):855-861.
  • 8Magli A, Forte R, Tortori A, et al. Epithelium-off corneal collagen cross-linking versus transepithelial cross-linking for pediatric keratoconus. Cornea 2013; 32(5): 597-601.
  • 9Salman AG. Transepithelial corneal collagen crosslinking for progressive keratoconus in a pediatric age group. J Cataract Refract Surg 2013; 39(8):1164-1170.
  • 10Spadea L, Mencucci R. Transepithelial corneal collagen cross-linking in ultrathin keratoconic corneas. Clin Ophthalmol 2012; 6:1785-1792.

二级参考文献33

  • 1Flamant F. Distribution of light in the retinal image. Arch Ophtal- mol Rev Gen Ophtalmol, 1956, 16 : 54-66.
  • 2Saad A, Saab M, Gatinel D. Repeatability of measurements with a double-pass system. J Cataract Refract Surg, 2010, 36: 28-33.
  • 3Vilaseca M, Peris E, Pujol J, et al. Intra- and intersession repeat- ability of a double-pass instrument. Optom Vis Sci, 2010, 87: 675-681.
  • 4Tomas J, Pinero DP, Alio JL. Intra-observer repeatability of opti- cal quality measures provided by a double-pass system. Clin Exp Optom, 2012, 95: 60-65.
  • 5Chylack LJ, Wolfe JK, Singer DM, et al. The lens opacities clas- sification system IlL The Longitudinal Study of Cataract Study Group. Arch Ophthalmol, 1993, 111 : 831-836.
  • 6Panlsson LE, Sjostrand J. Contrast sensitivity in the presence of a glare light. Theoretical concepts and preliminary clinical studies. Invest Ophthalmol Vis Sci, 1980, 19: 401-406.
  • 7de Waard PW, Ijspeert JK, van den Berg TJ, et al. Intraocular light scattering in age-related cataracts. Invest Ophthalmol Vis Sci, 1992, 33: 618-625.
  • 8Guirao A, Gonzalez C, Redondo M, et al. Average optical per- formance of the human eye as a function of age in a normal popula- tion. Invest Ophthalmol Vis Sci, 1999, 40: 203-213.
  • 9Artal P, Benito A, Perez GM, et al. An objective scatter index based on double-pass retinal images of a point source to classify cataracts. PLoS One, 2011, 6: e16823.
  • 10Diaz-Douton F, Benito A, Pujol J, et al. Comparison of the reti- nal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument. Invest Ophthalmol Vis Sci, 2006, 47: 1710-1716.

共引文献30

同被引文献67

引证文献9

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部