Er:YAG激光照射对1步法粘接系统在颈部牙本质的长期粘接效果影响 被引量:2

Effects of Erbium:YAG Laser Irradiation on Bond Durability of an All-in-one Bonding System for Cervical Dentin
下载PDF
导出
摘要 目的:用微剪切实验测评Er:YAG激光照射对1步法自酸蚀粘接系统在颈部牙本质的长期粘接效果的影响。方法:30颗离体磨牙切割获60片颈部牙本质切片,随机分为对照组(#600沙砾磨砂纸打磨)和激光组(Er:YAG激光照射)。每切片粘接8个树脂柱(Tri-S Bond),24h、7d、6月、1年后测微剪切粘接强度,one-way ANOVA和t-test统计分析结果(P=0.05)。走查扫描电镜观察粘接破折面。结果:Er:YAG激光照射牙本质表面呈鳞片状,激光组在6个月和1年后的粘接强度显著下降,低于该组24h和7d后,也低于对照组的结果。结论:Er:YAG激光照射影响了Tri-S Bond在颈部牙本质的长期粘接强度。 Objective:To investigate the effects of Er:YAG laser irradiation on micro-shear bond strength of an all-in--one bonding system for cervical dentin over a period of 1year.Methods:Sixty cervical dentin slices obtained from extracted human third molars were prepared.After surface treatments by Er:YAG laser irradiation or600-grit silicon paper polishing,the micro-shear bond strength of Tri-S Bond to cervical dentin were tested after24hours(24H),7days(7D),6months(6M)and 1year(1Y).The results were statistically analyzed using oneway ANOVA and t-test.Results:It was showed that bond strengths of lased dentin after 6Mand 1Ywere significantly lower than those of other groups.Conclusion:Er:YAG laser irradiation influenced the bond strength of TriS Bond to cervical dentin after 6months and 1year.
出处 《口腔医学研究》 CAS CSCD 北大核心 2016年第5期490-493,共4页 Journal of Oral Science Research
基金 深圳市战略新兴产业发展专项资金资助(编号:JCYJ20130402151227187)(编号:JCYJ20150525092941015)
关键词 ER:YAG 激光 颈部牙本质 1步法自酸蚀粘接系统 微剪切强度 Er:YAG laser Dentin Self-etching Micro-shear bond strength
  • 相关文献

参考文献12

  • 1Keller U, Hibst R. Experimental studies of the application of the Er:YAG laser on dental hard structures: (11) Light mi- croscopic and SEM investigations [J]. Laser Surg Med, 1989, 9 : 345 -351.
  • 2彭早霞,李宁,陈曦,堵安庆,米丛波,梁学萍.不同充填方法修复楔状缺损边缘微渗漏情况比较[J].口腔医学研究,2016,32(2):158-160. 被引量:18
  • 3Aoki A, Ishikawa I, Yamada T, et al. Comparison between Er: YAG laser and conventional technique for root carious treatment in vitro [J]. J Dent Res, 1998, 77 :1404-1414.
  • 4Martinez-Insua A, Da Silva Dominguez L, Rivera FG, et al. Differences in bonding to acid-etched or Er:YAG-laser -treated enamel and dentin surfaces [J]. J Prosthet Dent, 2000, 84 : 280-288.
  • 5Zhengdi He, Masayuki Otsuki, Alireza Sadr and Junii Taga- mi. Acid resistance of dentin after erbium: yttrium-alumi- num-garnet laser irradiation [J]. Lasers Med Sci, 2009, 24 (4) ; 507-513.
  • 6De Munck J, Van Meerbeek B, Yudbira R, Lambrecbts P, Vanherle G. Micro-tensile bond strength of two adhesive to Er:YAG laser vs. bur-cut enamel and dentin [J]. Eur J O- ral Sei, 2002, 110 : 322-329.
  • 7Romos RP, Chinelatti MA, Chimello DT, et al. Bonding of self-etching and total-etGhing systems to Er: YAG laser- irradiated dentin, tensile bond strength and scanning electron microscopy [J]. Braz Dent J, 2004, 15 ; S1-9-S1-20.
  • 8A Ishikawa, Y Shimada, RM Foxton, et al. Micro-tensile and micro-shear bond strengths of current self-etch adhe-sives to enamel and dentin [J]. Am J Dent, 2007, 20(3) 161-166.
  • 9A Sadr, Y Shimada, J TAgami. Effects of solvent drying time on micro-shear bond strength and mechanical proper- ties of two self-etching adhesive systems [C]. Dental Mate- rials Official Publication of the Academy of Dental Materials, 2007, 23(9): 1114-1119.
  • 10S Tsuchiya, T Nikayido, H Sonoda, et al. Ultrastructure of the dentin - adhesive interface after acid - based challenge [J]. J Adhes Dent, 2004, 6 : 183-190.

二级参考文献10