期刊文献+

可吸收棒治疗桡骨小头骨折效果观察 被引量:1

下载PDF
导出
摘要 目的观察可吸收棒治疗MasonⅡ、Ⅲ型桡骨小头骨折的效果及安全性。方法 100例MasonⅡ、Ⅲ型桡骨小头骨折患者,按入院时间分为对照组与观察组,各50例。观察组采用可吸收棒内固定治疗,对照组采用常规微型钢板螺钉内固定治疗。两组随访1年,观察1年后肘关节功能恢复及并发症情况。结果观察组术中出血量、住院时间、并发症发生率少于对照组,肘关节功能恢复优秀率(75.0%)明显高于对照组(44.9%),除住院时间、并发症发生率外,术中出血量和肘关节恢复优秀率组间差异有统计学意义。结论应用可吸收棒内固定治疗MasonⅡ、Ⅲ型桡骨小头骨折具有术中出血量少,术后肘关节功能恢复好,无需二次手术取出固定物的优点。
作者 吴丹海
出处 《中国乡村医药》 2016年第5期5-6,共2页
  • 相关文献

参考文献3

  • 1Herbortsson P,Josefsson PO,Hasserius R,et al. Fracturesof the radial head and neck treated with radial headexcision[J]. J Bone Joint Surg Am,2004,86(9):1925.
  • 2王思成,张友忠,杨国庆,何金国,方阳,刘祥飞,吴献民,杨笑宇.可吸收棒与Herbert螺钉修复桡骨小头骨折:治疗效应及经济学的比较[J].中国组织工程研究,2014,18(26):4153-4157. 被引量:12
  • 3Nordstr m P,Pohjonen T,T rm l P,et al. Shearloadcarrying capacity of cancellous bone after implantation ofself-reinforced polyglycolic acid and poly-L-lactic acidpins; experimental study on rats[J].Biomaterials,2001,22(18):2557.

二级参考文献28

  • 1梅国华,张长青,罗从风,蔡培华,范存义,姜佩珠,曾炳芳.MasonⅠ、Ⅱ型桡骨小头骨折非手术治疗的比较研究[J].中华手外科杂志,2005,21(3):151-153. 被引量:39
  • 2蔡晓冰,纪方,曹磊,佟大可,王秋根,张秋林,汪滋民,唐昊,汪方.微型钢板治疗MasonⅢ型桡骨头骨折的疗效分析[J].中国矫形外科杂志,2007,15(2):104-106. 被引量:18
  • 3Givissis PK,Symeonidis PD,Ditsios KT. Late results of absorbable pin fixation in the treatment of radial head fractures[J].Clinical Orthopaedics and Related Research,2008,(05):1217-1224.
  • 4Mason ML. Some observations on fractures of the head of the radius with a review of one hundred cases[J].British Journal of Surgery,1954,(172):123-132.
  • 5Hirvensalo E,B?stman O,Rokkanen P. Absorbable polyglycolide pins in fixation of displaced fractures of the radial head[J].Archives of Orthopaedic and Traumatic Surgery,1990,(05):258-261.
  • 6Jahn R,Diederichs D,Friedrich B. Resorbable implants and their use exemplified by fracture of the head of the radius[J].Aktuel e Traumatol,1989,(06):281-286.
  • 7Pelto K,Hirvensalo E,B?stman O. Treatment of radial head fractures with absorbable polyglycolide pins:a study on the security of the fixation in 38 cases[J].Journal of Orthopaedic Trauma,1994,(02):94-98.
  • 8Rehm KE,Hel ing HJ,Claes L. Report of the Biodegradable Implants Study Group[J].Aktuel e Traumatol,1994,(02):70-73.
  • 9Hel ing HJ,Prokop A,Schmid HU. Biodegradable implants versus standard metal fixation for displaced radial head fractures. A prospective,randomized,multicenter study[J].Journal of Shoulder and Elbow Surgery,2006,(04):479-485.
  • 10Broberg MA,Morrey BF. Results of delayed excision of the radial head after fracture[J].Journal of Bone and Joint Surgery-American Volume,1986,(05):669-674.