TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较 被引量:8

Monte Carlo-based comparison of radiation protection efficiency of lead glasses vs. lead mask for eye lens of doctor in different standing postures during transcatheter arterial chemoembolization
下载PDF
导出
摘要 目的:使用蒙特卡洛方法和三维体素人体模型研究医生在肝动脉化疗栓塞手术中不同站姿下的眼晶状体辐射剂量水平,并比较铅面罩和铅眼镜对于眼晶状体的辐射防护效果。方法:以介入医护人员为研究对象,并选取面对病人、左转45°、右转45°3种常用站姿,计算佩戴铅面罩、佩戴铅眼镜、眼睛无防护措施3种情况下,医生的眼晶状体年当量剂量和左右眼晶状体的吸收剂量。结果:无防护情况下,眼晶状体受到年当量剂量按照左转45°、面对病人和右转45°这3种情况依次减小,但均超过IBSS年剂量限值20 mSv。戴铅眼镜情况下,不同站姿眼晶体年当量剂量相似且接近IBSS年剂量限值。戴铅面罩情况下,不同站姿下所受剂量均较小。对于左右眼晶体吸收剂量比较,左转45°时,右眼晶体剂量率大于左眼;而其他两种站姿时,右眼均小于左眼晶体剂量。结论:为了减少医生在肝动脉化疗栓塞手术中眼晶状体所受到的辐射剂量,在保证手术质量前提下,若无防护措施,应尽量采用正面面对和右转45°站姿。建议医生手术时佩戴铅面罩,将眼晶状体当量剂量降到最低。如果没有铅面罩,需注意加强左眼晶体的防护。 Objective Transcatheter arterial chemoembolization (TACE) operation is widely used in current interventional radiation therapy, which may create high radiation dose in the eye lens of the operators, leading to the cloudy of the eye lens or even worse, cataract. In the study, the eye lens doses and differences for a doctor who was in different postures and used different eye protection wears during TACE were analyzed by using Monte Carlo method and 3D voxel phantom. Methods The annual equivalent doses and the absorbed doses of the left and right eye lens of the doctor wearing lead glasses, or lead mask, or nothing, each in different standing postures: facing 45° to the left, facing 45° to the right and facing the patient, were simulated and calculated. Results Without any protection, the equivalent doses for the eye lens of the doctor in three different standing postures were all larger than the dose limit 20 mSv, the reference value from International Bibliography of the Social Sciences (1BSS) in 2014, and decreased in the order of facing 45° to the left, facing the patient and facing 45° to the right. With lead glasses, the equivalent doses in different standing postures were close to the dose limit of IBSS; with lead mask, the equivalent doses were smaller. The absorbed doses of different eye lens were different: the doses of the left eye lens were less than those of the right lens for the doctor facing 45° to the left, while the dose results the left lens were greater than those of the right lens for the other two standing postures. Conclusion In order to reduce the eye lens dose without affecting the operation quality, doctors were suggested to wear lead mask, avoid turning left when operating in TACE without eye lens protections, and pay more attention to the left lens protection if lead mask is not available.
出处 《中国医学物理学杂志》 CSCD 2016年第6期553-558,共6页 Chinese Journal of Medical Physics
基金 国家自然科学基金(11375181 11375182)
关键词 肝动脉化疗栓塞 介入放射学 体素模型 蒙特卡洛 辐射剂量 眼晶状体 铅眼镜 铅面罩 transcatheter arterial chemoembolization interventional radiology voxel model Monte Carlo radiation dose eye lens lead glasses lead mask
  • 相关文献

参考文献16

  • 1CANTLEY J L, HANLON J, CHELL E, et al. Influence of eye size and beam entry angle on dose to non-targeted tissues of the eye during stereotactic X-ray radiosurgery of AMD [ J ]. Phys Med Biol, 2013, 58 ( 19): 6887.
  • 2IAEA BSS. Radiation protection and safety of radiation sources: international basic safety standards [ M ]. Vienna: IAEA, 2014.
  • 3薛茹,陈尔东,鞠金欣.眼晶状体新剂量限值对介入放射工作人员辐射防护的影响[J].中国辐射卫生,2015,24(3):223-226. 被引量:10
  • 4O' CONNOR U, GALLAGHER A, MALONE L, et al. Occupational radiation dose to eyes from endoscopic retrograde cholangio- pancreatography procedures in light of the revised eye lens dose limit from the International Commission on Radiological Protection [ J ]. Br J Radiol, 2013, 86(1022): 20120289.
  • 5胡盼盼,卓维海,孔燕,陈波,刘海宽,易艳玲.铅眼镜对介入放射工作人员眼晶状体的防护效果研究[J].中华放射医学与防护杂志,2014,34(12):927-930. 被引量:12
  • 6VAN ROOIJEN B D, DE HAAN M W, DAS M, et al. Efficacy of radiation safety glasses in interventional radiology[J]. Cardiovasc Intervent Radiol, 2014, 37(5): 1149-1155.
  • 7KONG Y, STRUELENS L, VANHAVERE F, et al. Influence of standing positions and beam projections on effective dose and eye lens dose of anaesthetists in interventional procedures [ J ]. Radiat Prot Dosim, 2015, 165(1-4): 276-278.
  • 8PELOWITZ B. Mcnpx user' s manual [ M ]. Los Alamos: Los Alamos National Laboratory, 2005: 1-79.
  • 9KU X, CHAO T, BOZKURT A. VIP-man: an image-based whole- body adult male model constructed from color photographs of the visible human project for multi-particle Monte Carlo calculations [J]. Health Phys, 2000, 78(5): 476-486.
  • 10ZHANG J, NA H, CARACAPPA F, et al. RPI-AM and RPI-AF, a pair of mesh-based, size-adjustable adult male and female computational phantoms using ICRP-89 parameters and their calculations for organ doses from monoenergetic photon beams[ J]. Phys Med Biol, 2009, 54(19): 5885-5908.

二级参考文献48

  • 1王进,杨春勇,许翠珍,余宁乐.部分介入放射X射线机的辐射防护性能检测与分析[J].中国辐射卫生,2007,16(3):318-319. 被引量:4
  • 2中华人民共和国国家质量监督检验检疫总局,GB18871-2002电离辐射防护与辐射源安全基本标准[S].北京:中国标准出版社,2002
  • 3den Boer A, de Feijter PJ, Serruys PW,et al. Real-time quantification and display of skin radiation during coro- nary angiography and intervention[J]. Circulation, 2001, 104(15) : 1779-1784.
  • 4Bakalyar DM,Castellani MD, Safian RD. Radiation expo- sure to patients undergoing diagnostic and interventional cardiac catheterization procedures [J]. Cathet Cardiovasc Diagn, 1997,42(2) : 121-125.
  • 5Hirshfeld JW Jr, Balter S, Brinker JA, et al. ACCF/ AHA/HRS/SCAI Clinical competence statement on physician knowledge to optimize patient safety and image quality in {luoroscopically guided invasive cardiovascular procedure[J]. Circulation, 2005,111 (4) : 511-532.
  • 6Vano E,Jarvinen H,Kosunen A,et al, Patient dose in in- terventional radiology:a European survey[J]. Radiat Prot Dosimetry. 2008,129(1-3) : 39-45.
  • 7Balter S.Stray radiation in the cardiac catheterization laboratory[J].Radiat Prot Dosim,2001,94(1-2):183-188.
  • 8International Commission on Radiological Protection.ICRP Publication 89.Avoidance of radiation injuries from medical interventional procedures[R].Oxford:Pergamon Press,2000.
  • 9Farah J,Struelens L,Dabin J,et al.A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists[J].Radiat Prot Dosim,2013,157(4):561-569.
  • 10McVey S,Sandison A,Sutton DG.An assessment of lead eyewear in interventional radiology[J].J Radiol Prot,2013,33(3):647-659.

共引文献29

同被引文献44

引证文献8

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部