期刊文献+

碳纳米管场发射测试方法对其性能的影响

Effects of test environment on the field emission properties of carbon nanotubes
下载PDF
导出
摘要 采用丝网印刷技术在金属基片上制备碳纳米管列阵薄膜,应用二极管结构对其场发射性能进行测试,并分析影响碳纳米管阴极场发射性能的因素。结果表明,随着测试次数的增加,碳纳米管阴极场发射性能会有一定程度的提高,同时场发射性能的稳定性增加;阴阳极距离15μm时,碳纳米管具有最好的场发射性能。 A diode structure experiment apparatus has been set up to test this cathode.The result showed that testing times and the distance between the cathode and anode in operation process seriously affect the field emission characteristics.It was found that the field emission of carbon nanotubes was enchanced with the testing times increased.The results revealed that the field emission characteristics is dependent on the distance between the cathode and anode.With the distance between the cathode and anode at 15 μm,carbon nanotube showed the optimal field emission characteristics.
出处 《应用化工》 CAS CSCD 北大核心 2016年第6期1201-1204,共4页 Applied Chemical Industry
基金 山西省青年科技研究创新基金(2013021004-3 2014021020-1) 山西省自然科学基金资助项目(2014011049-26)
关键词 碳纳米管 场发射 测试次数 阴阳极距离 carbon nanotube field emission testing times distance between the cathode and anode
  • 相关文献

参考文献16

  • 1Iijima S.Helical microtubes of graphitic carbon[J].Nature,1991,354(6348):56-58.
  • 2Dai H,Hafner J H,Rinzler A G,et al.Nanotubes as nanoprobes in scanning probe microscopy[J].Nature,1997,384(6605):147-150.
  • 3杨远超,刘亮,姜开利,范守善.基于碳纳米管长线场发射的真空测量[J].真空,2010,47(4):75-78. 被引量:4
  • 4Liu Y X,Liu J H,Zhu C C.Flame synthesis of varbon nanotubes for panel field emission lamp[J].Applied Surface Science,2009,255:7985-7989.
  • 5叶芸,肖晓晶,郭太良,黎威志,蒋亚东.碳纳米管表面化学镀银及场发射性能研究[J].功能材料,2012,43(9):1221-1224. 被引量:15
  • 6Rakhi R B,Lim X,Gao X,et al.Electron field emission from magnetic nanomaterial encapsulated multi-walled carbon nanotubes[J].Applied Physics A,2010,98(1):195-202.
  • 7Chela C L,Liang B,Lu D,et al.Amino group introduction onto multiwall carbon nanotubes by NH3/Ar plasma treatment[J].Carbon,2010,48(4):939-948.
  • 8Anshu S,Balram T,Vijay Y K.Dramatic improvement in properties of magnetically aligned CNT/polymer nanocomposites[J].Journal of Member Science,2010,361(1):89-95.
  • 9Shiozawa K,Neo Y,Okada M,et al.Fabrication and characteristics of novel graphite field emitters for application to electron beam pumped light sources[J].J Vac Sci Technol B,2007,25(2):668-669.
  • 10Mu H,Zhang X B,Lei W.High-current-density field emission from multiwalled carbon nanotubes by chemicalvapor deposition with effective aging treatment[J].J Vac Sci Technol B,2007,25(2):583-585.

二级参考文献47

  • 1Wei Y, Weng D, Yang Y C et al. Efficient fabrication of field electron emitters from the muhiwalled carbon nanotube yarns[J].Appl Phys Lett,2006,89(6): 063101-1-3.
  • 2Fan S S,Chapline M G, Franklin N R et al. Self-oriented regular arrays of carbon nanotubes and their field emission properties[J]. Science, 1999,283(5401):512-514.
  • 3Leck J H. Pressure Measurement in Vacuum Systems, 2nd ed [M]. London: Chapman and Hall, 1964,77-80.
  • 4Sehulz G J, Phelps A V. Ionization gauges for measuring pressures up to the millimeter range[J].Rev Sci Instrum, 1957,28(12): 1051-1054.
  • 5Redhead P A, Hobson J P, Komelsen E V. The Physical Basis of Ultrahigh Vacuum [M]. London:Chapman and Hall, 1968,287-310.
  • 6Zhang M,Fang S L,Zakhidov A Aet al. Strong, transparent multifunctional, carbon nanotube sheets[J]. Science, 2005, 309(5738): 1215-1219.
  • 7Zhang X B, Jiang K L, Fang C etal. Spinning and processing continuous yarns from 4-inch wafer scale super-aligned carbon nanotube arrays [J]. Adv Mater, 2006, 18(12): 1505-1510.
  • 8Baptist R. A vacuum gauge with microtips: the orbitip gauge [J]. Vacuum, 1997,48(7-9):723-725.
  • 9Baptist R, Bieth C,Py C.Bayard-Alpert vacuum gauge with microtips[J].J Vac Sci Technol B, 1996,14(3): 2119-2125.
  • 10Dong C, Myneni G R. Field emitter based extractor gauges and residual gas analyzers[J].J Vac Sci Technol A,1999, 17(d)'2026-2033.

共引文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史