摘要
分析了不同类型的数据变化与变压器内部潜伏性故障的关系。建立了变压器状态预警模型,并制定了相应的状态检修策略,提高了变压器的运行可靠性。
The relationship between different types of data and transformer internal latent faults are analyzed. The warning model of transformer condition is established. The con- dition maintenance strategy is developed. The reliability of the transformer is improved.
出处
《变压器》
北大核心
2016年第6期56-60,共5页
Transformer
关键词
变压器
油色谱
状态
在线监测
Transformer
Oil chromatography
Cordition
On-line monitoring