摘要
分析了热力管网出现水力失调的原因,分别介绍了静态平衡阀、自力式压差控制阀、自力式流量控制阀的各自工作原理和特点,论述了在不同的热力管网中选用和设置不同调节阀门的原则。
The paper analyzed the heat pipe network appear hydraulic imbalance,respectively,and introduced the static balance valve,self operated pressure difference control valve,self operated flow control valve of the respective principles and characteristics. It discussed in different heating pipe network in the selection and installation of different regulating valve principle.
出处
《林业科技情报》
2016年第2期75-77,共3页
Forestry Science and Technology Information
关键词
水力失调
静态平衡阀
自力式压差控制阀
自力式流量控制阀
hydraulic imbalance
static balance valve
self pressure differential control valve
self operated flow control valve