期刊文献+

硫酸盐硫同位素的MC-ICP-MS测定方法研究 被引量:4

Sulfur Isotope Measurement of Sulfates by Using High-Resolution MC-ICP-MS
下载PDF
导出
摘要 本文详细介绍了硫同位素的MC-ICP-MS测定方法,包括样品和标样的准备以及仪器质量歧视的校正。并对测试过程中的谱学干扰、基体效应、浓度效应等进行了评估。在对基体效应的探究中,详细阐述了基体对硫同位素比值和硫信号值的影响。在对浓度效应的探究中,介绍了硫的浓度效应校正曲线,使得硫同位素的MC-ICP-MS测试过程更为简便快捷。 The techniques for the sulfur isotope measurement by using MC-ICP-MS have been reported in this paper. The reference and sample preparation methods as well as the instrumental mass bias correction procedures have been introduced. In addition,the spectral interferences,matrix effects and concentration effects on the analytical results of the sulfur isotope measurement have been evaluated. Especially,the effects of matrices on both isotopic ratios and signal intensities have been explored and the sulfur concentration effect correction curve has been introduced in order to measure sulfur isotopes more rapidly by using MC-ICP-MS.
出处 《矿物岩石地球化学通报》 CAS CSCD 北大核心 2016年第3期465-472,401,共8页 Bulletin of Mineralogy, Petrology and Geochemistry
基金 国家自然科学基金项目(41573004) 国家科技基础条件平台北京离子探针中心开放基金项目(DDK14-40)
关键词 MC-ICP-MS 硫同位素 谱学干扰 基体效应 浓度效应 MC-ICP-MS sulfur isotope spectral interferences matrix effects concentration effects
  • 相关文献

参考文献36

  • 1Aggarwal J K, Sheppard D, Mezger K, Pernicka E. 2003. Precise and accurate determination of boron isotope ratios by multiple collector ICP-MS: Origin of boron in the Ngawha geothermal system, New Zealand. Chemical Geology, 199(3-4) : 331-342.
  • 2Albar:de F, Telouk P, Blichert-Toft J, Boyet M, Agranier A, Nelson B. 2004. Precise and accurate isotopic measurements using multiple- collector ICPMS. Geoehimica et Cosmoehimica Aeta, 68(12) : 2725 - 2744.
  • 3Bian X P, Yang T, Lin A J-, Jiang S Y. 2015. Rapid and high-precision measurement of sulfur isotope and sulfur concentration in sediment pore water by multi-collector inductively coupled plasma mass spec- trometry. Talanta, 132:8-14.
  • 4Canfield D E. 2001. Biogeochemistry of sulfur isotopes. Reviews in Min- eralogy and Geochemistry, 43 ( 1 ) : 607- 636.
  • 5Clough R, Evans P, Catterick T, Evans E H. 2006. 834S measurements of sulfur by multicolleetor inductively coupled plasma mass spectrom- etry. Analytical Chemistry, 78(17) : 6126-6132.
  • 6Coplen T B, Krouse H R. 1998. Sulphur isotope data consistency im- proved. Nature, 392 ( 6671 ) : 32.
  • 7Craddock P R, Rouxel O J, Ball L A, Bach W. 2008. Sulfur isotope measurement of sulfate and sulfide by high-resolution MC-ICP-MS. Chemical Geology, 253 (3-4) : 102-113.
  • 8Ding T, Valkiers S, Kipphardt H, De Bivre P, Taylor P D P, Gonfian-tini R, Krouse R. 2001. Calibrated sulfur isotope abundance ratios of three IAEA sulfur isotope reference materials and V-CDT with a reassessment of the atomic weight of sulfur. Geochimica et Cosmo- chimica Acta, 65(15) : 2433-2437.
  • 9Fraser M M, Beauchemin D. 2009. Evidence supporting the occurrence of Coulomb fission during conventional sample introduction in inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry, 24(4) : 469-475.
  • 10Fritz P, Drimmie R J, Nowicki V K. 1974. Preparation of sulfur dioxide for mass spectrometer analyses by combustion of sulfides with copper oxide. Analytical Chemistry, 46( 1 ) : 164-166.

二级参考文献4

共引文献66

同被引文献60

引证文献4

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部